24 February, 2010
RBH Access Technologies Inc.
10 of
26
TB61_PC-
100 for AxiomV™
Input Groups
Create input groups by assigning the associated IOC inputs with partitions
There should be three groups of inputs for every partition:
1) Interior zones.
2) Exterior zones.
3) Entry zones.
Axiom Links
Create four links for every partition.
1) Disarm Link
– Disarm Interior, Disarm Exterior, Disarm Entry.
2) Home Link
– Disarm Interior, Arm Exterior, Disarm Entry.
3) Evening Link
– Disarm Interior, Arm Exterior, Arm Entry.
4) Away Link
– Arm Interior, Arm Exterior, Arm Entry.
In order to synchronize the Paradox Alarm Panel with the Axiom Access Control
the Paradox inputs are mapped to virtual IOC-16 using the first eight panels on
the point number table
For example, Paradox panel input #88 would be mapped to IOC address #10
input #8. This input would be located in one of eight partitions in the Paradox
panel programmed through the Paradox keypad.
Dipswitch Setting
To allocate a block of IOC addresses for use by the Paradox alarm panel you
must first determine how many inputs you will need. For example if you need to
monitor the first 64 inputs you will need 64÷
16 (inputs per IOC) = 4 IOC‟s. The
first IOC address will be # 5 representing inputs 1-16 and the last IOC address
will be #8 representing inputs 49-64. Use the
to determine the dipswitch settings.