Setting the grinding angle
The ES 2000 is delivered with a factory pre-set grinding angle of 90°. Use this
setting or choose another setting for grinding by unscrewing the lock nut (5)
and turning the adjustment screw (4) until the scale (6) displays the desired
angle.
The illustration below shows a set angle of 90°. The surface above the number
90 is set parallel to the base plate of the ES 2000.
ATTENTION!
Make sure that, after setting the grinding angle, the lock nut (5) is tightened
properly again, otherwise the grinding angle may change while the unit is
operational, which can cause undesirable grinding results.