Part 1. ST60 Instruments – Chapter 4. Tridata
A22004
26
ST60 Instruments Service Manual 83142-1
No fail codes are generated since stage 2 is an audio/visual check. The following can,
however, be used as a guide to isolate a problem:
Failure Mode
Action
No illumination
Check TR14, TR13, TR15 and associated components. Check all LEDs.
Keypad Illumination failure (LCD
Check TR14, TR13, R22 and R23.
illumination will also be degraded).
Check LED1-6 for open circuit.
Keypad illumination OK
Check TR14, TR15, RN3, R24.
but degraded LCD illumination.
Check LED 7 and 8 for open circuit.
No beep when key pressed.
Replace keyswitch.
LCD segment(s) missing
Check LCD solder pins for poor/dry joints.
completely.
Check IC3 for unsoldered pins.
Faint LCD segments
Check LCD pins for shorts.Check IC3 for shorts.
Press Key 1 and Key 2 together momentarily to progress to self-test stage 4 (stage 3
not supported on this instrument).
Self-test stage 4
Note: A known good speed and depth transducer must be connected for this test.
A. The unit should display ‘TEST 4’ for 1 second.
B. Transducer tests are performed.
Spin the paddle wheel within 15 seconds of entering this test. If there is a problem with
the speed interface “FAIL 10” is shown and the following tests should be carried out.
Check
Failure Mode
Action
Voltage at 12V_SPD
No voltage or low voltage (<11.0)
Check TR17, TR20, R63 and R64.
with 12V battery supply.
L7
Open circuit
Replace L7.
D3
Open circuit
Replace D3.
Voltage at TEMP pin
Outside acceptable range of
Check L9 for open circuit.
0.76 to 1.00V (18 - 25 degrees C)
Check R14.
AVREF
Outside acceptable range of 2.5V +/- 0.25v
Check TR4. Check R74, 17.
Provided the depth transducer is in water where a good echo should be seen, the test
will pass, otherwise “FAIL 8” is shown and the following tests should be carried out:
Check
Failure Mode
Action
Pulses at pins 8 and 10 of IC4
No pulses
Check R68, 76, 77. Check IC4 and IC5 and
replace if suspect (trace pulses from IC3).
Pulses at drain of TR5
No pulses
Check L5 and R19 for open circuit.
Replace TR5. Replace T1.
Pulses at drain of TR6
No pulses
Check L5 and R19 for open circuit.
Replace TR6. Replace T1.
Pulses at DEPTH+ and DEPTH-
No pulses
Check C11 and C12 for open circuit. Replace T1
Depth receiver output pulses
No pulses
Fault diagnosis of the depth receiver circuit
at pin 11 of IC5
requires specialist knowledge and the units
should be returned to Raytheon Marine Ltd.
Press Key 1 and Key 2 together momentarily to exit self-test.
Summary of Contents for ST60
Page 12: ...Part1 ST60Instruments Chapter1 Speed A22001 8 ST60 Instruments Service Manual 83142 1...
Page 20: ...Part1 ST60Instruments Chapter2 Depth A22002 16 ST60 InstrumentsService Manual 83142 1...
Page 28: ...Part1 ST60Instruments Chapter3 Multi A22003 24 ST60 InstrumentsService Manual 83142 1...
Page 36: ...Part1 ST60Instruments Chapter4 Tridata A22004 32 ST60 InstrumentsService Manual 83142 1...