SNV-12 Operations Manual
6-14
6.3.18
Network Password Configuration
PASS <current_pw> <new_pw>
The network access password can be changed from the serial command line using the PASS
command. The password is required for accessing any SNV-12 web pages that allow the user
to change configuration. The user must know the current password in order to set the new
password. The arguments to the PASS command are the current password followed by the
new password. To keep the password secure, it is suggested that the serial terminal software
be restarted after setting the password so that the serial buffer is cleared and the pass command
cannot be recalled from the buffer.
NOTE: CPM-3 Software Version 1.04 and later enables SNV-12 system
control via the Ethernet network port. It is HIGHLY recommended that
the default factory password be changed before connecting to a
network.
Example:
PASS B0wser! Sp0t?
; Command sent to the SNV-12.
Change from the current password
“B0wser!” to new password “Sp0t?”
OK
; Status returned.
The default password is
lightfoot
. This is the password as shipped from the factory and also the
password that is reset by Jumper J16. See Section 3.12.4 for instructions regarding the Reset to
Factory Defaults operation.
The password must be less than 40 characters and does not require any specific combination of
characters. Any character that is a capital or lower case letter, number, or symbol can be used.
The password is case sensitive
Lost or Forgotten Passwords
There is a method for retrieving the current password if it‟s forgotten, but physical access to the
unit is required. If the unit is set temporarily in the Manufacturing Test Mode (Set CPM-3
SW1-7 to on and cycle the main power), the PASS command, entered with no arguments, will
cause the SNV-12 to respond with the current password.
Be sure to take the unit out of Manufacturing Test mode so that the unit can return to proper
voting operation. Set CPM SW1-7 back to OFF and cycle unit power (the switches are only
read at power up).
Alternatively, the unit can simply be set back to complete default settings via jumper J16.
Summary of Contents for SNV-12
Page 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Page 22: ......
Page 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Page 75: ...SNV 12 Operations Manual 3 47 ...
Page 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Page 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Page 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Page 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Page 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Page 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Page 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Page 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Page 130: ......
Page 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Page 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Page 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Page 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Page 202: ......