SNV-12 Operations Manual
6-1
6
SNV-12 Remote Operation
6.1
General
This Section explains the RS-232 serial remote control capabilities of the SNV-12 and details
all control commands to the voter and the corresponding responses from the voter. The web
browser control and status interface is also covered.
6.2
Serial Port
All voter functions and complete voter status can be accessed via the SNV-12‟s RS-232 serial
port. The serial port connector, located at the rear of the unit, is a DB-9 female connector
wired as a DCE interface. The word is fixed at 8 data bits, one stop bit, no parity and Flow
Control - none. Baud rates selectable on the CPM Module are 300, 1200, 2400, 4800, 9600,
19200, 38400, and 57600. Switch 1, positions 1,2,3 on the CPM module are used to set the
baud rate. Switch 1, position 4 is used to enable the voter‟s Remote Mode, or it will ignore
incoming commands. See section 2.9.3.1. Connections are made via backplane connector P1;
a female 9-pin D-sub connector. Standard DCE pin out is used. See 2.8 and Table 3-4 for
more details.
6.3
Remote Command Set
The following commands make up the SNV-12 Remote Command Set:
SEL
Manually force a site or sites to be voted
ENABLE
Enable/disable a site from being voted
TXSEL
Select site or sites for console transmission
–Stays active until disabled
MOM_TXSEL Select site for console audio transmission
–Stays active until Holdover Timer expires
RPT
Turn Repeat Mode on or off
CFG
Report CPM dipswitch configuration
STAT
Report site status (Signal Quality, Positive COR,
speech present, voted, etc)
VER
Report software version number
AS
Enable/disable automatic status reporting
Summary of Contents for SNV-12
Page 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Page 22: ......
Page 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Page 75: ...SNV 12 Operations Manual 3 47 ...
Page 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Page 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Page 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Page 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Page 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Page 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Page 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Page 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Page 130: ......
Page 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Page 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Page 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Page 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Page 202: ......