Chapter 3: Getting Started & Adjusting the Display
3-3
Swi
tc
hin
g t
h
e
D
is
p
la
y
On a
n
d Of
f
Automatic Gain cannot be adjusted on the repeater display, but Manual
Gain can be.
STC cannot be adjusted on the repeater display.
Depth offset, speed and temperature calibration (see Section 7.4) cannot
be set on the repeater display.
Frequency can be selected on either master or repeater display, but the
same frequency is used on both displays.
Range adjustment can be made on either master or repeater display, but
any changes made are used on both displays.
Simulator mode is repeated from the master, but cannot be selected on the
repeater display.
➤
To set the fishfinder display as a master or repeater:
1. Press the
MENU
key, then press the
SONAR SET UP
soft key. The sonar set
up pop-up window is displayed.
2. Use the trackpad to move the selection bar over the option
SONAR HSB
MODE
. The HSB mode soft keys are displayed.
3. Press the appropriate soft key to set the display as a
MASTER
or
REPEATER
.
4. Press
ENTER
twice to return to the default display.
Chart Mode
➤
To switch the display on in chartplotter mode, press and hold the
POWER
key
until the unit beeps. The keys light up, the Raychart graphic is displayed,
followed by the caution:
CAUTION:
Raychart chart displays are based on cartographic data that
C-MAP believes to be accurate. However, you should not rely on these
displays as your primary source of navigation. Rather, your Raychart
should be used only as a backup to official government charts and
traditional methods of navigation.
When you have read and understood the caution, press the
CONTINUE
soft key.
The chart is displayed.
If this is the first time the chartplotter has been turned on, and no chart card is
installed, the display shows the small-scale world map and the default soft
keys. Otherwise, the display shows the selected chart area and any data that
were displayed when the display was last used.
Summary of Contents for HSB L755
Page 2: ......
Page 30: ...1 18 HSB Series L755 and L760 Fishfinder Database Lists...
Page 76: ...2 46 HSB Series L755 and L760 Fishfinder Transmitted Data...
Page 114: ...3 38 HSB Series L755 and L760 Fishfinder Review Your Passage Plan...
Page 128: ...4 14 HSB Series L755 and L760 Fishfinder MOB...
Page 196: ...8 8 HSB Series L755 and L760 Fishfinder Worldwide Support...
Page 200: ...A 4 HSB Series L755 and L760 Fishfinder Appendix A Specifications...
Page 206: ...B 6 HSB Series L755 and L760 Fishfinder Appendix B Using the Auxiliary Junction Box...
Page 212: ...C 6 HSB Series LCD Color Display Appendix C C MAP Chart Card Features...