NautoPilot® 5000 Series
102-890.NG001-NG003
Operator Manual
10000001052
92
Edition: 003
2.3.7
Test of NautoPilot® Operator Unit
Note:
This test is not used to test the Autopilot control functions.
This test serves for testing the function of the display, the LEDs, the rotary knob and
the buttons.
This test should be activated from time to time or in the case of an assumed
malfunction of an operation feature such as the display, the LEDs, the rotary knob
or a button.
The test can only be started in a non-automatic mode, i.e. Manual, Standby or
Over- ride only.
Start the test by pressing the SET and Illumination buttons simultaneously
for approx. 5 seconds.
The display lights up in red, green, blue and black for approx. 15 seconds. Parallel
to this the LEDs for Heading, Course and Track light up green and yellow and the
LED for alarm and SET request light up yellow.
During this test it is possible to check that the LEDs are lit and that the display
shows no blank/dark dots.
The following tests request several different operator actions to test the function of
the rotary knob, the buttons at the front plate and some softkey functions on the
display. Each single test task is displayed as a request to the operator.
Operator actions must be performed within a set time window - this is shown with a
countdown bar.
The test is finished:
- Pressing the SET button at any time or
- double click (double touch) on the touch screen at any time or
- or if the time window exceeds its limit.
The test is aborted/finished and the previous display is shown again.
If defect dots on the Autopilot display result in lack of or wrong information, the
replacement of the NautoPilot® Operator Unit is recommended.
Single dot failures do not legitimate for warranty claims. See Pixel Defect Policy,
Service Manual.