3 Configuration & Maintenance
Edition:002
21
10000000584
Element
Description
VDR channel
Sets the channel identificaton of the eLog.
Select the channel identification (1-255) which is
reported to the VDR when sending logbook data.
Default value is
3
.
Location
Sets the location attribute of the eLog.
Select the location attribute which is reported to
the VDR when sending logbook data. Default val-
ue is
Logbook
.
Activate Syslog
Activates or deactivates publishing of syslog mes-
sages.
Check the checkbox to activate publishing of sys-
log messages with the error counters defined for
IEC 61162-450 communication. Default value is
true. If set to false, no syslog messages are sent.
4.
Select the softkey
Safe
.
► The device reboots.
5. Close the browser window.
► After approximately 3 minutes the electronic logbook can be used again. The
changed settings are now active.
3.1.3
Configure AIS
Requirements
• You must be logged in as an administrator.
About this task
The eLog is able to read IEC 61162-1/-2 data over a RS485 serial port.
Procedure
1. Select the softkey
AIS
in the Gateway Configuration menu, see
.
► The menu
AIS
opens.