Technical Data
16
MI3
3.3
Electrical Specification
For an overview to the capabilities of the communication boxes, see section 2.1
3.3.1
Comm Box, all models
Voltage Supply
8 to 32 VDC
Power Consumption
max. 6 W
Alarm Output
1 potential-free relay output, 48 V / 300 mA
Relay with wear-free contacts (solid state relay) for target temperature or head ambient
temperature, electrically isolated from power supply
USB Interface
Version: 2.0
Connector on the board: type Mini-B
3.3.2
Comm Box (metal)
Analog Outputs
Output 1
0 to 5/10 V output for head ambient temperature and object temperature
electrically
not
isolated from power supply
TC
Thermocouple (type J, K, R, or S)
Output 2
0 to 20 mA (active), or
4 to 20 mA (active), or
0 to 5 V, or
0 to 10 V
electrically
not
isolated from power supply
External Inputs
3 inputs are available useable in different modes:
FTC1-3
Emissivity control: 3 bit digital coded, 0 to V
SS
FTC1
Emissivity control: analog, 0 to 5 V
DC
FTC2
Ambient temperature compensation analog: 0 to 5 V
DC
FTC3
for trigger/hold/laser functions, 0 to V
SS
3.3.3
Comm Box (DIN 6TE, analog)
Analog Outputs
Output 1 to 4
0 to 20 mA (active), or
4 to 20 mA (active), or
0 to 5 V, or
0 to 10 V
Each output is galvanically isolated from the other and from power supply!
1.800.868.7495