Appendix
MP150
Protocol
33
7
Appendix
7.1
List of User Commands
In this table the interface (sector) refers with n = 1
…
3 to the analog outputs and n = 0 to the digital
interface output.
Description
Code
Para-
meter
Explanation
Factory
default
Firmware
Revision
Poll parameter
G
G<code> Example: GES
Ambient
temperature for
ambient radiation
correction
A
float
In case of AC1 this parameter defines the
background temperature in the range of:
min. range ... max range.
27.0
3.20
Ambient
compensation
Control
AC
d
d = 0 ... no compensation
d = 1... with compensation by command
d = 2... with compensation by the voltage
input
0
3.20
Alarm Flag
AF
nd
n=0..3: sector/interface
d=0: reset the alarm flag
d=1: set the alarm flag, it will be held
according to the hold mode
0
Ambient
compensation
bottom (Low)
range
AL
integer
In case of AC2 this parameter defines the
temperature that corresponds to 0 V at the
voltage input.
min. range
3.21
Ambient
compensation top
(High) range
AH
integer
In case of AC2 this parameter defines the
temperature that corresponds to 5 V at the
voltage input.
max. range
3.21
Alarm Reset
AR
-
Resets all alarm flags,
like AF n0 for all n
-
Accumulation Time AT
dddd
averaging time in tenth of a second
0
MP50:
limited to
6000 (600 s)
Accumulation
Lines
AV
integer
Has the same effect as AT but is more
precisely by giving the lines instead of
time.
Limited to 9000 lines.
0
Condense N-to-1
Lines
AVX
n x y
Has the same effect as AV, but offers the
option to average, maximum or minimum
n = n lines to condense (like for AV)
x = 0: calculate the average (like AV n)
x = 1: take the maximum
x = 2: take the minimum
x = 3: advanced maximum with y as
threshold
0 0 0
3.30
BootP Client
BootPClient d
d = 0: switch off
d = 1: switch on
1 (on)
3.43