background image

8  

VARIO Remote Controller (VRC) : 

Optional Accessory 
Full instructions provided with VRC when supplied 

Note : Reset button will not remove a PIN if one is present 
Note : Unless detailed as part of the functionality, if an invalid or 

blocked command is attempted, both LEDs will flash RED 

Press again for 4 seconds to 
disable manual buttons – 
must be done within 5 
minutes of remote disable 

Summary of Contents for VARIO2 i16

Page 1: ...closed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons VARIO2 Specifications...

Page 2: ...urple Wires Telemetry input Volt free dry contact or TTL input Lens Selection VARIO is factory set and delivered with a 35 beam width angle To alter to 10 simply remove interchangeable lens ILS To alt...

Page 3: ...dicate 3 sensitivity settings Low 1 Flash Med 2 Flashes High 3 Flashes Solid Red for Photocell disabled Status Indicator LEDS On Off 3 x Push Solid Amber Each Push cycles between On and Off On Green O...

Page 4: ...mming Mode Full factory default including No PIN The illuminator has two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are...

Page 5: ...Press again for 4 seconds to disable manual buttons must be done within 5 minutes of remote disable This will NOT remove PIN if present...

Page 6: ...PIN Programming Mode Press Status Button for 4 seconds Enter valid PIN charact ers x 4 Green to Intermittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters r...

Page 7: ...dicate the following status LHS SOLID GREEN Power Applied LHS FLASHING GREEN Remote control IR received problem RHS FLASHING AMBER Indicates unit is in programming mode Programming Mode Only RHS SOLID...

Page 8: ...luminator connection red ve black ve Ensure power is 12 24V AC or DC For Vario 16 variants 24V only AC or DC Ensure telemetry wires are shorted out or valid telemetry input zero volt or TTL is applied...

Page 9: ...lts Page 6 LED Status Indicators Feedback System Page 8 VARIO Remote Controller VRC Page 10 PIN Function Detail Page 12 Manual Control Buttons Page 17 Disabling Manual Buttons Page 18 Power Up Functio...

Page 10: ...EN62471 Risk Group 2 Do not stare at the lamp Avoid exposure or use appropriate shielding eye protection Risk Group 2 for cornea lens infrared hazard For VAR i2 VAR i4 VAR i6 and VAR i8 variants haza...

Page 11: ...ration wiring and final set up using manual push buttons on the illuminator or VARIO Remote Controller VRC VRC is an optional accessory The external cable cannot be replaced If it is damaged and the c...

Page 12: ...angle which they will produce when inserted into VARIO2 Please handle ILS lenses with care and do not touch optical film Only 1 ILS lens can be inserted into the product at anytime The product cannot...

Page 13: ...tep 4 Telemetry Input Orange Purple As default the telemetry input will be wired together so that the unit turns on off automatically via the photocell If required to be activated by PIR or alarm syst...

Page 14: ...ttons Step 7 Set PIN If Required Can only be done with the optional VARIO Remote Control VRC LED Status Indicators Feedback system There are two tri coloured LEDs visible on the base of the VARIO2 ill...

Page 15: ...G GREEN Remote control IR receiver problem Max VRC distance is 8m 26ft RHS FLASHING AMBER Indicates unit is in programming mode Programming Mode Only RHS SOLID AMBER Indicates that a valid command is...

Page 16: ...supplied Note Reset button will not remove a PIN if one is present Note Unless detailed as part of the functionality if an invalid or blocked command is attempted both LEDs will flash RED Press again...

Page 17: ...each lamp The PIN is set by using the Vario Remote Control VRC There are five buttons characters on the remote that can be used for this purpose Note Unless detailed as part of the functionality if a...

Page 18: ...acters will not be recognised and will not reduce the number of flashes When the PIN is set the illuminator will revert to Programming Mode When a PIN is Set Using the remote you can access the illumi...

Page 19: ...into operating mode you will not be able to go back to programming mode without recycling the power Note If you forget your pin and need to make adjustments to the illuminator you need to do full Re...

Page 20: ...f maximum Factory Default is 100 2 Photocell Control 3 levels 25 Lux on 50 Lux off 10 Lux on 30 Lux off 5 Lux on 15 Lux off and photocell disable 3 Turn LED indicators on off 4 Illuminator Reset Optio...

Page 21: ...tempted both LEDs will flash Red Mode Selection by using LHS Button A momentary press of LHS button turn LHS LED solid RED and enters the user into the Illuminator Settings Modes In these modes you ca...

Page 22: ...s of RHS BUTTON will take you through the available options to get to the required setting you want within that mode The Illuminator will stay at this setting level providing you do not push the RHS B...

Page 23: ...previously before selecting manual controls The following modes are available Power Level Mode LHS LED Solid RED RHS LED 20 Power Setting 1 Flash GREEN 40 Power Setting 2 Flashes GREEN 60 Power Settin...

Page 24: ...S LED Flashing RED RHS LED Solid RED Keep RHS BUTTON depressed for 4 seconds RHS LED stays solid RED and then after 4 seconds both LEDs flash AMBER to show the illuminator has been reset This operatio...

Page 25: ...be accessed in the normal way by a continuous 4 second press RHS Button o Pushing this button will cause both indicator LEDS to flash RED Once the 30 minutes has expired any button push LHS or RHS wil...

Page 26: ...inutes after the last button press RESET Options There are Two Re set options for resetting your VARIO2 illuminator Settings Re set Pressing and holding the RESET BUTTON on the remote control or using...

Page 27: ...d with the Product Model Dependant not to scale dimensions rounded to nearest mm Optional Bracketry not to scale other Bracketry also available VUB Pole VUB Wall VUB Plate VUB PSU Plate Wall Mount PTZ...

Page 28: ...ion 100W max 84W max 46W max 42W max 25W max 13W max 24W max 10W max 11W max Input 24V AC DC 12 24V AC DC 12 24V AC DC 12 24V AC DC Weight 3 1kg 6 8lbs 1 65kg 3 61lbs 950g 2 1lbs 600g 1 3lbs Number of...

Page 29: ...difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably rated to product check page 20 for specifications If longer cables used ensure sufficient...

Page 30: ...ting mode LHS Green Solid Status LEDs can be turned off in either mode check if no LEDs visible LHS SOLID GREEN Power Applied LHS FLASHING GREEN Remote control IR receiver problem RHS FLASHING AMBER I...

Page 31: ...down Model and serial number of illuminator Camera make and model Camera Lens make and model If the Raytec illuminator or remote control is still not delivering the required performance please contact...

Page 32: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Reviews: