Raytec Vario W8 Installation And Setup Manual Download Page 1

Contents

Page 2 

Quick Set-Up and Factory Defaults

Pages 3 - 4 

Complete Set-Up and Installation

Page 5 

VARIO Remote Controller (VRC)

Page 6 

Feedback System

Page 7 

Bracketry

Page 8 

Specifications

Page 9 - 11 

Troubleshooting

VARIO illuminator with 35˚ beam angle IHD 
60˚ beam angle IHD 

VARIO Remote Controller for additional programming of the unit 
80˚ beam angle IHD 
120˚ beam angle IHD

Box Contents:

Accessories: 

(optional)

Installation and Setup guide
VARIO Series

VARIO w8

VARIO i8

VARIO w4

VARIO i4

VARIO w2

VARIO i2

Summary of Contents for Vario W8

Page 1: ...age 7 Bracketry Page 8 Speci cations Page 9 11 Troubleshooting VARIO illuminator with 35 beam angle IHD 60 beam angle IHD VARIO Remote Controller for additional programming of the unit 80 beam angle I...

Page 2: ...con guration and nal set up using VARIO Remote Controller VRC this is an optional accessory Factory Default Set Up 35 Beam Angle Max 100 Power Telemetry Input closed Photocell sensitivity MID Status L...

Page 3: ...e when inserted into VARIO Please handle IHD lenses with care and do not touch optical lm Only 1 IHD lens can be inserted into the product at anytime The product cannot accommodate mutliple IHD lenses...

Page 4: ...on polarity sensitive short circuit light on TTL input Orange TTL ve Purple TTL ve GND 0V Light on 3V Light off Step 6 Photocell following output White Yellow Volt free output normally open day to nor...

Page 5: ...erational requirements Timer Setting The timer function allows the illuminator to be triggered via the telemetry input and remain on for a pre de ned period of time Photocell Disable Lamp operates fro...

Page 6: ...d a FLASHING RED status LED indicates that there is a problem with the input voltage Please note once the voltage problem has been corrected the user must disable remote control set up or power the un...

Page 7: ...etry not to scale VARIO 2 series VARIO 4 series VARIO 8 series Standard Bracketry not to scale dimensions rounded to nearest mm Wall Mount Dome Mount Ptz Mount Pole Mount 51mm 53mm 53mm 47mm 72mm 104m...

Page 8: ...120 Consumption 48W max 24W max 12W max Input 12 24V AC or DC 12 24V AC or DC 12 24V AC or DC Weight 1 8kg 4lbs 1kg 2 2lbs 650g 1 4lbs Environment IP66 IP66 IP66 Dimensions L x W x D 135 x 180 x 68 2...

Page 9: ...e Infra Red lamps working in high brightness conditions Ensure power supply is suitably rated to product check page 8 for speci cations If longer cables used ensure suf cient voltage is provided to al...

Page 10: ...LED ashes 1 second on 1 second off SOLID GREEN Power Applied FLASHING GREEN Remote IR receiver problem SOLID RED Internal LED Fault Detected FLASHING RED Voltage supply problem detected Please note o...

Page 11: ...tions distance between remote and unit may need to be reduced Battery failure Check battery on remote CR2025 Test 3 volt battery replace if necessary Ensure battery has clean contacts Remote failure T...

Reviews: