background image

(.

NOTE – If no buttons are pressed within 2 minutes the illuminator times out 
and returns to the previous mode it was in – either Programming Mode or 
Operating Mode. 

Disabling the Manual Buttons  : 

If the Illuminator is in Operating Mode, once the disable manual buttons 
command is executed the buttons will be disabled after 30 minutes.  This 
is to allow the user to re-enable manual buttons if required. 

   During this 30 minutes the button response will be the following 

- LHS Button

o

Illuminator Settings Mode cannot be accessed. A momentary
press of the button will not be recognised and the indicator LEDs
will not change

o

Illuminator Security Mode can be accessed in the normal way
by a continuous 4 second press

- RHS Button

o

Pushing this button will cause both indicator LEDS to flash RED

    Once the 30 minutes has expired any button push (LHS or RHS) will cause 
    both indicator LEDs to flash RED and the manual buttons are fully 
    disabled 

Disabling the Manual Buttons Using the Remote : 

The manual buttons can be disabled using the remote. 
Once the illuminator is put into Operating mode if the disable remote 
control Set Up button (see diagram on Page 8) is pressed again and held 
for 4 seconds the manual buttons will be disabled. This is shown by both 
indicator LEDs flashing RED after 4 seconds. 
Note : This command can only be used within 5 minutes of the illuminator 
being put into Operating Mode using the Remote Control 
(If the Manual Buttons are already Disabled , both LEDs will flash RED 
straight away) 

Summary of Contents for VARIO 2 VAR2-i8-3

Page 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons VARIO2 Specifications Tabl...

Page 2: ...ity sensitive Orange and Purple Wires Telemetry input Volt free dry contact or TTL input Lens Selection VARIO is factory set and delivered with a N beam width angle B3 B N A7 G remove interchangeable...

Page 3: ...dicate 3 sensitivity settings Low 1 Flash Med 2 Flashes High 3 Flashes Solid Red for Photocell disabled Status Indicator LEDS On Off 3 x Push Solid Amber Each Push cycles between On and Off On Green O...

Page 4: ...ramming Mode Full factory default including No PIN The illuminator has two modes Programming Mode when the remote control can be used and Operating Mode when most of the remote control functions are d...

Page 5: ......

Page 6: ...PIN Programming Mode Press Status Button for 4 seconds Enter valid PIN charact ers x 4 Green to Intermittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters r...

Page 7: ...ogramming Mode and Operating Mode the two LED s indicate the following status LHS SOLID GREEN Power Applied LHS FLASHING GREEN Remote control IR received problem RHS FLASHING AMBER Indicates unit is i...

Page 8: ...ces are followed at all times Check polarity of illuminator connection red ve black ve Ensure power is 12 24V AC or DC For Vario 16 variants 24V only AC or DC Ensure telemetry wires are shorted out or...

Page 9: ...aults Page 6 LED Status Indicators Feedback System Page 8 VARIO Remote Controller VRC Page 10 PIN Function Detail Page 12 Manual Control Buttons Page 17 Disabling Manual Buttons Page 18 Power Up Funct...

Page 10: ...Group 2 Do not stare at the lamp Avoid exposure or use appropriate shielding eye protection Risk Group 2 for cornea lens infrared hazard For VAR i2 VAR i4 VAR i6 and VAR i8 variants hazard distance i...

Page 11: ...E 9 1D B D G F D175 9 ED 24V AC DC For Vario 16 variants 24V AC or DC only 4 5D5 3 697EB1D9 G9B9 7 1 4 69 1 C5D E EC9 7 1 E1 EC8 buttons on the illuminator or VARIO Remote Controller VRC VRC 9C 1 D9 1...

Page 12: ...4 G9D8 D85 1 7 5 G8938 D85I G9 B 4E35 G85 9 C5BD54 9 D 51C5 81 4 5 5 C5C G9D8 31B5 O 1 4 4 D D E38 D931 69 I 5 C 31 25 9 C5BD54 9 D D85 B 4E3D 1D 1 ID9 5 85 B 4E3D 31 D 133 41D5 E D9 5 5 C5C 1D D85 C1...

Page 13: ...ep 4 Telemetry Input Orange Purple As default the telemetry input will be wired together so that the unit turns on off automatically via the photocell If required to be activated by PIR or alarm syste...

Page 14: ...ttons Step 7 Set PIN If Required Can only be done with the optional VARIO Remote Control VRC LED Status Indicators Feedback system There are two tri coloured LEDs visible on the base of the VARIO2 ill...

Page 15: ...NG GREEN Remote control IR receiver problem Max VRC distance is 8m 26ft RHS FLASHING AMBER Indicates unit is in programming mode Programming Mode Only RHS SOLID AMBER Indicates that a valid command is...

Page 16: ...Accessory Full instructions provided with VRC when supplied Note Reset button will not remove a PIN if one is present Note Unless detailed as part of the functionality if an invalid or blocked command...

Page 17: ...ication Number to be set for each lamp The PIN is set by using the Vario Remote Control VRC There are five buttons characters on the remote that can be used for this purpose Note Unless detailed as pa...

Page 18: ...cters will not be recognised and will not reduce the number of flashes When the PIN is set the illuminator will revert to Programming Mode When a PIN is Set Using the remote you can access the illumin...

Page 19: ...into operating mode you will not be able to go back to programming mode without recycling the power Note If you forget your pin and need to make adjustments to the illuminator you need to do full Re s...

Page 20: ...maximum Factory Default is 100 2 Photocell Control 3 levels 25 Lux on 50 Lux off 10 Lux on 30 Lux off 5 Lux on 15 Lux off and photocell disable 3 Turn LED indicators on off 4 Illuminator Reset Option...

Page 21: ...empted both LEDs will flash Red Mode Selection by using LHS Button A momentary press of LHS button turn LHS LED solid RED and enters the user into the Illuminator Settings Modes In these modes you can...

Page 22: ...of RHS BUTTON will take you through the available options to get to the required setting you want within that mode The Illuminator will stay at this setting level providing you do not push the RHS BU...

Page 23: ...reviously before selecting manual controls The following modes are available Power Level Mode LHS LED Solid RED RHS LED 20 Power Setting 1 Flash GREEN 40 Power Setting 2 Flashes GREEN 60 Power Setting...

Page 24: ...LED Flashing RED RHS LED Solid RED Keep RHS BUTTON depressed for 4 seconds RHS LED stays solid RED and then after 4 seconds both LEDs flash AMBER to show the illuminator has been reset This operation...

Page 25: ...e accessed in the normal way by a continuous 4 second press RHS Button o Pushing this button will cause both indicator LEDS to flash RED Once the 30 minutes has expired any button push LHS or RHS will...

Page 26: ...nutes after the last button press RESET Options There are Two Re set options for resetting your VARIO2 illuminator Settings Re set Pressing and holding the RESET BUTTON on the remote control or using...

Page 27: ...d with the Product Model Dependant not to scale dimensions rounded to nearest mm Optional Bracketry not to scale other Bracketry also available VUB Pole VUB Wall VUB Plate VUB PSU Plate Wall Mount PTZ...

Page 28: ...tion 100W max 84W max 46W max 42W max 25W max 13W max 24W max 10W max 11W max Input 24V AC DC 12 24V AC DC 12 24V AC DC 12 24V AC DC Weight 3 1kg 6 8lbs 1 65kg 3 61lbs 950g 2 1lbs 600g 1 3lbs Number o...

Page 29: ...difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably rated to product check page 20 for specifications If longer cables used ensure sufficient...

Page 30: ...ng mode LHS Green Solid Status LEDs can be turned off in either mode check if no LEDs visible LHS SOLID GREEN Power Applied LHS FLASHING GREEN Remote control IR receiver problem RHS FLASHING AMBER Ind...

Page 31: ...p 4 Call Ray for further assistance Note down Model and serial number of illuminator Camera make and model Camera Lens make and model If the Ray illuminator or remote control is still not delivering t...

Page 32: ...0DLQ 2IILFH 7 PDLO VDOHV UD OHG FRP ZZZ UD OHG FRP s...

Reviews: