Raytec VARIO 2 PoE Quick Installation Manual Download Page 1

1  

        

www.rayteccctv.com

 

                                         

Raytec Global  Tel : +44(0) 1670 520055

 

                                                                                                       Americas Tel : +1 613 270 9990 

 

 

 

POE

    

Quick  InstallInstallation  Guide 

 

Safety Information: 

 

 

 

 

White Light and IR Variants (850nm & 940nm) 

Caution – Risk Group 2. Avoid Exposure / use protection.  
See Safety Information in FULL Instruction Guide for more details. 

 

 

 

 

Box Contents:

  

VARIO2  POE Illuminator , 60° beam angle ILS, User Guide 
(ILS: Interchangeable Lens  System)  
Optional Accessories:  Remote Controller for additional programming;   
80˚ beam and 120˚ beam angle ILS; Bracketry 

 

Factory Default Set-Up: 

35˚ Beam Angle ; Max 100% Power 
Photocell sensitivity – MID; Telemetry Input Closed (Premium variants only) 
Status LEDs – ON ; No PIN Set 
Programming function will auto-disable after 7 Days (if no manual buttons used) 
 

VARIO2 Specifications Table:

 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

 
 
 
 

 

 
 
 
 

See Page 26 and 27 in Full Instruction Guide 
 

PoE Detection: 

There is a switch on the 

VAR2-PoE-w8-1, i8-1

 and 

i8-1-C

 illuminators  which 

can  be  used  to  change  the  PoE  detection  resistance  of  the  illuminator 
(24.9KΩ is the factory default setting). 

The majority of PSE equipment requires a detection resistance of 24.9KΩ to 
establish a PoE link.  Some models of PSE equipment require12.5KΩ. 

For 24.9 KΩ, slide switch to the LEFT (factory default – as shown).  For 12.5 KΩ, 
slide switch to the RIGHT. 

Summary of Contents for VARIO 2 PoE

Page 1: ...t Set Up 35 Beam Angle Max 100 Power Photocell sensitivity MID Telemetry Input Closed Premium variants only Status LEDs ON No PIN Set Programming function will auto disable after 7 Days if no manual b...

Page 2: ...owing contact Volt free output Non polarity sensitive Orange and Purple Wires Telemetry input Volt free dry contact or TTL input Lens Selection Select different beam angle if required VARIO is factory...

Page 3: ...itivity Then Solid Red for Photocell disabled Status Indicator LEDS On Off 3 x Push Solid Amber Each Push cycles between On and Off On Green Off Red Factory Re set Does not Re set PIN 1 x Long Push 4...

Page 4: ...Full factory default including No PIN The illuminator has two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled s...

Page 5: ...5 www rayteccctv com Raytec Global Tel 44 0 1670 520055 Americas Tel 1 613 270 9990...

Page 6: ...30 minutes Create or Change PIN Prog Mode Press Status Button for 4 seconds Enter valid PIN character x 4 Green to Intermittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down th...

Page 7: ...Programming Mode Only RHS SOLID AMBER Indicates that a valid command is being received Programming Mode Only LHS FLASHING RED Voltage supply problem detected LHS SOLID RED Illuminator LED fault detect...

Page 8: ...ollowed at all times Check rating of PoE power source is suitably rated or 24V dc Premium only Check PoE resistance detection switch is correctly rated Check LED status indicators for relevant informa...

Reviews: