background image

 

17 

 

 

7.2 

Pulsed output 

The output is off by default. When the VTR6 is triggered it waits for a delay and 
then pulses the output. This delay can be set from 0.01ms to 999ms. 

Retrigger delay is the minimum allowed time from one trigger to the next. Any 
triggers that happen too soon after the previous trigger are ignored. The 
retrigger delay is set in multiples of 100us. 

The delay, pulse width, retrigger delay and pulse intensity are all 
configurable. 

7.3 

Switched output 

Switched mode uses the trigger input to switch the output on or off using 
the timing of the trigger signal. The output brightness can be varied from 
0% to 100%. 

The VTR6 applies the same duty cycle and pulse width limits as for pulse mode, 
to prevent the light being damaged. 

7.4 

Internal trigger timer 

An internal timer is available for continuous triggering in pulse mode. The 
period of this timer is configurable. 

Note: 

The internal timer is mostly used when synchronising a camera using the 

trigger output. Generally, it is not possible to run the light strobe from this 
timer while free running the camera as they will not remain synchronised and 
the images will have very variable intensity. 

When this timer is turned on, the light strobe pulse and the trigger output are 
both triggered by this timer. External triggers still work. 

When troubleshooting during development, it is sometime useful to set this 
timer to give regular light pulses.  

7.5 

Trigger input 

The trigger input is used as follows: 

 

Mode 

Trigger input 

Output 

 

Switched 

Trigger input = off 

Output is off if P flag = 1 
Output is on if P flag = 0 

Trigger input = on 

Output is on if P flag = 1 
Output is off if P flag = 0 

 

Pulsed 

Trigger rising edge 

Pulse is triggered if P flag = 1 

Trigger falling edge 

Pulse is triggered if P flag = 0 

Note: 

The P flag inverts the sense of the trigger input. 

Summary of Contents for PULSESTAR VTR6

Page 1: ...PULSESTAR VTR6 Installation Guide Issue 005...

Page 2: ...For your notes...

Page 3: ...5 Sicherheitsleitfaden f r Augen Haut 6 3 5 1 IEC BS EN 62471Risikogruppen 7 3 5 2 Produkbeschriftung 7 4 S curit 8 4 1 Chaleur 8 4 2 lectrique 8 4 3 G n ralit s 9 4 5 Conseils de s curit pour les ye...

Page 4: ...19 8 2 2 Network broadcast packets 20 9 Webpage configuration Ethernet versions only 21 9 1 Main page 22 9 2 General setup page 22 9 3 Light output configuration page 23 9 4 Trigger output configurati...

Page 5: ...f features Throughout thismanual referencestothe VTR6refertoallvariantsinthe VTR6 range unless otherwise stated The convention for the product number is The convention for standard VTR6 product number...

Page 6: ...e electricalisolationofinputs including triggering and communications ports therefore please observe the following guidance Computer equipment that is connected to the communication or trigger ports m...

Page 7: ...er topersonalhealthordamage toother equipment If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 2 3 1 Disclaimer Thisinfor...

Page 8: ...VTR6 850 14 VTR6 850 28 Exempt VTR6 W 12 VTR6 W 28 2 4 2 Product labelling The infra red versions of this product are labelled The white versions of this product do not require a warning label MODERA...

Page 9: ...l ausgeschlossen ist und stellen Sie sicher dass Luft frei um das Ger t zirkulieren kann 3 2 Elektrik Das VTR6 verf gt ber keine vollst ndige elektrische Trennung der Eing nge einschlie lich Trigger u...

Page 10: ...en EmpfangvonRundfunk bertragungen erm glicht 3 3 Allgemein DasVTR6darfnicht inAnwendungeneingesetzt werden beidenenes durch einenAusfalldesGer tszueiner Gefahrf rdieGesundheit von Personen oder zur B...

Page 11: ...alle VariantendesVTR6beim Betrieb mit vollerLeistung und maximalerBetriebsdauer Risikogruppe 2 VTR6 850 14 VTR6 850 28 Ausnahme VTR6 W 12 VTR6 W 28 3 5 2 Produkbeschriftung Die Infrarotversionen dies...

Page 12: ...ucher par accident et veillez ce que l air circule librement autour de l unit 4 2 lectrique La VTR6 ne poss de pas d isolation lectrique compl t des entr es notamment des ports de d clenchement et de...

Page 13: ...r sidentielle peut causer des interf rences radio Ce type d utilisation doit tre vit sauf si des mesures particuli res sont prises par l utilisateur pour restreindre les missions un niveau qui permet...

Page 14: ...ce groupe de risque et s assurer qu aucun dommage corporel ne peut survenir proximit de la lampe 4 5 1 Groupes de risque IEC BSEN62471 Lesdispositionssuivantess appliquent touteslesvariantesdu VTR6 f...

Page 15: ...e VTR6 5 1 Heatsinking The approximate heat dissipation of the VTR6 can be calculated as follows HD 36 x BR x PW x TF 2 Where HD Heat dissipation W BR Brightnessofthe light output PW Strobe pule width...

Page 16: ...le assembly is provided by Raytec then the wire colours will be as shown below Bulkhead connector pin ETH option RS232 Wire colour std cable assy 6 7 8 9 Power Power Black Blue Grey Pink Green White 2...

Page 17: ...or if surge or transient interference greater than 60V may occur on the power supply lines additional surge protection should be provided 6 1 1 Power up surges The VTR6 will draw current surges from t...

Page 18: ...d across TRGI and TRGI the trigger input islogic0 off Tosee howtoset up the light totrigger ona 0 1transition risingedge ora 1 0 transition fallingedge refer toSection7 5 Triggerinput Thetrigger input...

Page 19: ...up to 24V can be blocked 6 4 Ethernet option The Ethernet connection is 10Base T and runs at 10Mbits per second 6 5 Serial option The RS232 connections are as follows The communications port should b...

Page 20: ...ly for short periods and at low duty cycles sothat the lightingdoes not overheat and get damaged In pulse mode the duty cycle is limited by ignoringtriggers which are too soonafter the previoustrigger...

Page 21: ...orcontinuoustriggeringinpulse mode The period ofthistimer isconfigurable Note The internal timer is mostly used when synchronising a camera using the trigger output Generally it is not possible to run...

Page 22: ...output is triggered at the same time as the light strobe output The delay and pulse width for this signal can be controlled independently of the light pulse 7 7 Factory settings The default VTR6 confi...

Page 23: ...ion Select Properties iv From the list select Internet Protocol TCP IP and select Properties IfObtainan IP address automatically isset thenDHCP isprobablyused However there maybe analternative fixed I...

Page 24: ...he first twoevents the message isbroadcast Onthe third it isa reply toa singleIP address An enquiry message is a UDP packet from source port 30310 destination port 30311 with the message body Gardasof...

Page 25: ...from a standard web browser suchasInternet Explorer The IP address of the VTR6 must be known see Section 8 Ethernet address Ethernet versions only Open a web browser window and type the IP address fo...

Page 26: ...below 9 2 General setup page The general setup page allows the webpage protection password to be set or cleared and the internal trigger to be set up Also any Ethernet command from Section 10 Configu...

Page 27: ...o non volatile memory Some measured valuesare displayed onthispage and anexample ofthe page is shownbelow 9 4 Trigger output configuration page Thispage allowsthe parameters for the trigger output to...

Page 28: ...eted It isrecommended that thehostwaitsforthe symbolbeforesendingthe next command UDP communications are not guaranteed to arrive so the host software must be able to cope with lost messages Using the...

Page 29: ...e of full brightness RW1 s Where s setting in percent s 0 to 100 Set pulse mode The output can be set up topulse ona trigger input The delayfrom trigger to the start of the pulse the length of the pul...

Page 30: ...liseconds For example TT1 200 Set the internal trigger to 200ms 5Hz TT1 1S Set the internaltrigger to1second 1Hz Save the settings to memory AW The results of the RW RT RE and TT commands are all save...

Page 31: ...eriod STc Reports settings for a single channel c 1 to select light strobe output c 2 to select a trigger output signal Simulate an Input Trigger TR1 Simulatesa trigger pulse Ifthe channelisinpulse mo...

Page 32: ...ord from one to six letters A value of 65 is A 66 is B and soonto90is Z Report internal temperatures AT Eachofthe three internalLEDPCBshasa temperature sensor and the AT command reportsa stringwith th...

Page 33: ...hernet messages GR GR Clear any error conditions EY EY65 66 Set webpage password to AB VR VR Read the firmware version RW RW1 50 Set channel 1 to 50 switch mode RT RT1 3 100us 50 Set light to strobe w...

Page 34: ...mumswitchedvoltageVceo 24V Load current should be externally limited to 50mA maximum Note These ratings are the absolute maximum permitted 11 2 Restrictions The minimum pulse delay for the light pulse...

Page 35: ...be incorrect Err 33 The VTR6 is too hot The VTR6 has a thermal cut out which operates around 65 C to 70 C depending on conditions Note Any other errors are internal errors 11 4 Event Codes Event messa...

Page 36: ...32...