5.3. Default Info
No.
Description
Default
(1)
Scanned device name
Raytac AT-UART
(2)
Base UUID
0x9E, 0xCA, 0xDC, 0x24, 0x0E, 0xE5, 0xA9, 0xE0,
0x93, 0xF3, 0xA3, 0xB5, 0x00, 0x00, 0x40, 0x6E
(3)
Service UUID
0x0001
TX characteristic: 0x0003; RX characteristic: 0x0002
(4)
Baud rate
9600bps,n,8,1
(5)
Status of flow control
Disabled
(6)
RF TX power
+4dBm
(7)
32.768Khz oscillator
Using internal RC with 1,000ms calibration time
(8)
Logic of BT connecting indicator
Output set as logic low when BT is connecting
(9)
PHY mode
1Mbps
(10)
Logic of wake-up pin
Set logic low to wake up in deep sleep
(11)
Idle time
Forever idle with no timeout
(12)
Time of scanning paired device
Forever scanning for paired device with no timeout
(13)
Time of scanning all devices
Forever scanning for all devices with no timeout
(14)
Status of DC-to-DC converter
Disabled
(15)
Connection interval mode
Set at min. 20ms and Max. 75ms for Peripheral
20ms/40ms usage
(16)
Idle LED pattern
0.1sec on / 3.9sec off
(17)
Connecting LED pattern
0.2sec on / 1.8secs off
(18)
LED pattern for scanning
paired device
1sec on / 1sec off
(19)
LED pattern for scanning
all devices
0.1sec on / 0.1sec off
(20)
Serial number
Display “ no data! ” string
(21)
ADC value
Value varies from input voltage between
0x0000 ~ 0x03FF
(Hex)
.
(22)
State of response
Enabled
Summary of Contents for MDBT42Q-AT-UART-M