Raypak 6350 Series Installation & Operating Instructions Manual Download Page 1

INSTALLATION & OPERATING

INSTRUCTIONS

Catalog No. RP6000.552F

Effective: 11-22-13

Replaces: 06-28-13 

  P/N 241377 Rev. 8

92-103778-03-10

FOR YOUR SAFETY:

Do not store or use gasoline or other flammable vapors and

liquids or other combustible materials in the vicinity of this or any other appliance. To

do so may result in an explosion or fire.

Model Series

5350, 6350, 

6350HC, 8350,

8350HC & 8360

Heat Pump

Pool & Spa  

Heater

US

C

LISTED

R

NOTE:

The instructions in this manual are for the use of qualified individuals specially trained and experienced

in the installation and maintenance of this type of equipment and related system components. Installation and

service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install,

service, or maintain this equipment.

This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a

safe place for future use.

Summary of Contents for 6350 Series

Page 1: ...C 8350 8350HC 8360 Heat Pump Pool Spa Heater US C LISTED R NOTE The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maint...

Page 2: ...2 Rev 8 reflects the following Changes to Model Series on front cover Tables A and B on page 9 Wiring Diagram on page 21 Wiring Diagram on page 22 Additions None Deletions None...

Page 3: ...4500 MAXIMUM 4500 MAXIMUM 4500 MAXIMUM Free Chlorine PPM 2 to 3 2 to 3 2 to 3 Total Dissolved Solids PPM 3000 MAXIMUM 3000 MAXIMUM 3000 MAXIMUM Free Chlorine MUST NOT EXCEED 5 PPM In salt water chlor...

Page 4: ...ly 12 System Start Up 13 Seasonal Start Up or Annual Check 13 Summer Shutdown 13 Freeze Protection 13 System Drain Down 13 Continuous Pump Operation 13 Maintenance 14 Air Coil Cleaning 14 Cabinet Care...

Page 5: ...d the heat pump pool heater CAUTION Elevated water temperature can be hazardous The U S Consumer Product Safety Commission has these guidelines 1 Spa water temperatures should never exceed 104 F 40 C...

Page 6: ...ulation of cold discharge air back into the evaporator coil will greatly reduce the unit s heat ing capacity and efficiency This unit features an up flow discharge for quiet operation Air is pulled up...

Page 7: ...low the control panel for precise power requirements for your unit and for ampacity and over current protection requirements All wiring must be in accordance with the National Electrical Code NFPA No...

Page 8: ...ONCRETE PAD SEE PAD SPECS UNIT HIGH WIND LOAD RESTRAINT DETAIL 1 SEE HIGH WIND LOAD RESTRAINT DETAIL 1 2 1 2 MIN SPACING TYP 4 VIBRATION ISOLATION PADS TYP EA CORNER COVERED UNIT HEIGHT BETWEEN 37 1 2...

Page 9: ...outlet to facilitate service and cold weather drain down 5 Operate the pump and check the system for leaks Pressure Drop For system pressure drop information refer to Table B below CAUTION The heat pu...

Page 10: ...ximately 5 minutes Refrigerant Low Pressure Control Stops the com pressor if refrigerant suction low side pressure falls too low as a result of a malfunction loss of charge or extreme cold conditions...

Page 11: ...ly 8 10 cooler than the air entering the unit If not see the Troubleshooting Section Controls Digital Models Your heat pump pool heater incorporates digital safety controls and indicators to ensure it...

Page 12: ...ntil you see F _C By pressing the UP or DOWN key you can switch to F or C Once the temperature display mode has been programmed it will be displayed for approximately 5 seconds then the digital displa...

Page 13: ...e of both To do this reset the time clock dial for the longer running time or manually operate the pump with the timer override switch Since the heat pump pool heater capacity and efficiency are both...

Page 14: ...After the desired temperature is reached return the unit to normal operation of 8 10 hours per day Maintenance The following maintenance procedures are designed to keep your unit operating at a high...

Page 15: ...the longer running time or manually operate the pump with the timer override switch Since the unit capaci ty and efficiency are both greater at higher ambient air temperatures run time should be set t...

Page 16: ...w backwash The unit will show HP6 after 6 HP faults This will stop the unit for protection FLo FL3 Possible causes The filter is in backwash position The filter pump is stopped The filter is dirty Sho...

Page 17: ...HECK VALVE CHEMICAL INTRODUCTION WATER OUT TO POOL OR SPA Fig 6 For systems with pumps of less than 2 HP under 80 gpm no external bypass is required Connections are 2 inch unions Plumb the heat pump p...

Page 18: ...SPA Fig 7 For systems with pumps of 2 HP or greater over 80 gpm an external bypass is required Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump pool heater Connections are...

Page 19: ...19 Fig 8 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater...

Page 20: ...20 Fig 9 Pool Piping for Heat Pump Pool Heaters Multiple Primary Secondary UNITS UNITS UNITS...

Page 21: ...W FAN RELAY AND ASSOCIATED WIRING W 1000S110 02 25 13 04 NR NR ZJW 06 MODELS 5350 6350 8350 05 REVISED TERMINATION OF BLUE WIRES TO TRANSFORMER ZJW W 1000S119 04 11 13 W 1000S131 08 07 13 06 JHB REVIS...

Page 22: ...0S131 08 07 13 07 NR NR JHB 07 SHEET NO MODELS 5350 6350 8350 8360 05 ADDED VOLTAGE MONITOR AS OPTION ZJW W 1006S001 02 23 12 ADDED NEW FAN RELAY AND ASSOCIATED WIRING 06 W 1000S110 02 25 13 ZJW REVIS...

Page 23: ...23 Wiring Diagram 208V 230V Three Phase Analog Models...

Page 24: ...24 Wiring Diagram 208V 230V Three Phase Digital Models...

Page 25: ...25 Wiring Diagram 460V Three Phase Analog Models...

Page 26: ...ns on the heat pump pool heater wiring block For a 3 wire control use the COMMON SPA and POOL connections on the heat pump pool heater wiring block Heater Settings 1 Make sure the heater is disabled o...

Page 27: ...27...

Page 28: ...Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Heat Pump Service 1 800 260 2758 Litho in U S A 28...