SeaTalk connected with its own power supply
S
eaTalk
SMART
PILOT
D10440-2
1
2
1.
Course computer power supply via breaker / fuse
2.
SeaTalk power supply via breaker / fuse rated 5 A or less
Care points:
• Connect data (yellow) and screen (grey) at SeaTalk terminals.
• Do not connect SeaTalk power (red) to the course computer.
• Cut back and insulate unconnected power wire.
Note:
Use correct fuse The fuse supplying the SeaTalk system
MUST be rated at 5 A or less.
3.9 NMEA 0183 connection
The SPX autopilot is compatible with NMEA 0183 devices, it
provides a 4800 baud rate input/output. Connections are made to
the connector panel underneath the removable cover.
FLUXGATE
FAULT
SLEEP
FAULT
NMEA
NMEA 0183
NMEA 0183
D10460-2
Note:
You must not connect more than one piece of equipment to
the NMEA 0183 in connection.
FastHeading connection
If you wish to use MARPA (radar target acquisition) functions on a
system without an autopilot connected using SeaTalk
ng
then you
will require a dedicated FastHeading connection. The connection
uses NMEA 0183 and is made between a compatible Raymarine
Cables and connections
33