12.1 RSW series wind transducer configuration
The RSW series of wind transducers requires configuration to ensure
readings are presented relative to vessel heading.
On a non-rotating mast where a heading sensor is present, the wind
transducer will automatically compensate for any offset between installation
angle and vessel centerline (heading).
On a non-rotating mast where no heading sensor is present and the
transducer has not been installed facing directly forwards, it is important
that an offset is applied to account for the difference between the mast’s
centerline and the transducer’s installation angle.
On a non-rotating mast, if poor heading sensor readings are affecting wind
readings, vessel heading can be ignored. However, an offset must be
applied to account for the difference between the vessel’s centerline and
the transducer’s installation angle.
On a rotating mast a heading sensor is required so that wind readings
compensate for mast angle. It is important that an offset is applied to account
for the difference between the mast’s centerline and the transducer’s
installation angle. The transducer will automatically compensate for the
difference between heading and mast angle.
Non-rotating mast example
1.
Vessel/mast centerline.
2. Offset angle.
Note:
Offset only needs to be entered if there is no heading sensor.
Rotating mast example
1.
Vessel centerline.
2. Mast centerline.
3.
Mast rotation.
4.
Offset angle.
Note:
A heading sensor and, where applicable, offset angle is required.
12.2 Configuring RSW wind using LightHouse 4
display
The RSW wind transducer can be configured using an Axiom display, running
LightHouse™ 4, version 4.5 or later.
The RSW wind transducer configuration is initiated from the
[Network]
settings menu:
[Homescreen > Settings > Network]
1. Select the
RSW Wired Gateway
from the network list.
2. Select
[Configure settings]
from the Pop-over options.
3. If your vessel has a rotating mast:
i.
Enable the
[Rotating mast]
toggle switch.
ii. If applicable, enter the offset value for your transducer.
• A vessel heading sensor is required for rotating masts.
42
Summary of Contents for RSW-Wired
Page 2: ......
Page 4: ......
Page 16: ...CHAPTER 4 PARTS SUPPLIED CHAPTER CONTENTS 4 1 Parts supplied page 17 16...
Page 36: ...CHAPTER 10 GROUND CONNECTION CHAPTER CONTENTS 10 1 Gateway ground connection page 37 36...
Page 45: ...CHAPTER 13 MAINTENANCE CHAPTER CONTENTS 13 1 Service and maintenance page 46 Maintenance 45...
Page 68: ......
Page 71: ...WEEE Directive 8 What s in the box 17 Wind transducer Configuration 42 44 Wire stripping 39...
Page 72: ......
Page 73: ......