Chapter 8: Installation
169
8.9 Integrated System Checks
Chart Display - RL70RC, RC520
When you have connected your display unit to the required equipment ensure
that position data is available at the display via NMEA or SeaTalk.
To confirm your chartplotter is operating correctly, perform the following
checks:
1. Without a chart card fitted, select the Chart display mode and select a
suitable range scale. Verify that the world map is visible.
Use the trackball to check cursor movement and normal scrolling action.
2. To ensure that the display is responding to position data:
Press
FIND SHIP,
check the cursor is fixed on the vessel symbol which is
correctly positioned at the centre of the chart display.
3. Insert a chart cartridge for the area of your vessel.
Use the
RANGE
key to zoom-in to check that the chart data is being
displayed.
Received Data
If either SeaTalk or NMEA In is connected, verify that the expected data is
displayed.
1. Press
DISPLAY
and select the
NAV DATA WINDOW ON.
Check that the expected data is displayed.
2. If heading data is connected, select Chart mode and check it is displayed in
the heading data box, or select Radar mode and check heading is displayed
in the Status Bar.
Transmitted Data
If SeaTalk or NMEA Out is being transmitted to other equipment, check that
the data is being received correctly.
An NMEA Out connector is used to transmit navigation data. The NMEA
Output cable should be connected to the upper, left connector on the rear of the
display unit.
Note:
The NMEA Output cable is fitted with a ferrite clamp to ensure EMC
conformance.
Integrated System
Checks
Summary of Contents for RL70C
Page 2: ...HSB Series LCD Display Owner s Handbook Document number 81163_1 Date 1st September 1999...
Page 64: ...50 HSBSeriesLCDDisplay...
Page 154: ...140 HSBSeriesLCDDisplay...
Page 184: ...170 HSBSeriesLCDDisplay...
Page 190: ...176 HSBSeriesLCDDisplay...
Page 200: ...186 HSBSeriesLCDDisplay...