from the unit to the vessel's battery or distribution
panel.
• For power cable extensions, it is recommended that a
minimum
wire gauge of 16 AWG (1.31 mm
2
). For cable
runs longer than 15 meters, you may need to consider
a thicker wire gauge (e.g. 14 AWG (2.08 mm
2
), or 12
AWG (3.31 mm
2
) ).
• An important requirement for all lengths of power
cable (including any extension) is to ensure that there
is a continuous
minimum
voltage of 10.8 V at the
product’s power connector, with a fully flat battery at
11 V.
Important:
Be aware that some products in your
system (such as sonar modules) can create voltage
peaks at certain times, which may impact the voltage
available to other products during the peaks.
Grounding
Ensure that you observe any separate grounding advice
provided in the product’s documentation.
More information
It is recommended that best practice is observed in all
vessel electrical installations, as detailed in the following
standards:
• BMEA Code of Practice for Electrical and Electronic
Installations in Boats
• NMEA 0400 Installation Standard
• ABYC E-11 AC & DC Electrical Systems on Boats
• ABYC A-31 Battery chargers and Inverters
• ABYC TE-4 Lightning Protection
4.4 Handset station connection
A Raymic handset can be connected to each Handset
station connection (HS 1 / HS 2). Your radio is supplied
with the equipment to create a full handset station (i.e.:
Raymic handset, Adaptor cable and Passive speaker).
Additional accessories can be purchased to create a
second handset station.
1.
Base station
2. Passive speaker (1 x supplied and available as
accessory: A80542)
3.
Raymic handset (1 x supplied and available as
accessory: A80289)
4.
Handset station adaptor cable with RCA Audio (1 x
supplied and available as accessory: A80297)
5. Raymic handset extension cable (Available optional
accessories: A80290, A80291 or A80292)
6. Panel mount fixings kit (1 x supplied and available
as a Spare: R70438)
Connecting handsets and cables
Follow the steps below to connect handsets and
extension cables together.
1. If fitted, unscrew and remove the dust cap from the
relevant connector.
2. Ensure the cable connectors are correctly orientated,
before insertion.
3. Ensure connectors are fully inserted, before locking..
4. Tighten locking collars by Rotating clockwise.
Handset extension cables
Handset station cabling can be extended using
approved extension cables.
The maximum length of cable from the Handset to the
Base station should not exceed 50 m (164 ft)
29
Summary of Contents for Ray 90
Page 1: ......
Page 2: ......
Page 4: ......
Page 12: ...12...
Page 18: ...18...
Page 32: ...32...
Page 60: ...60...
Page 64: ...64...
Page 65: ...Chapter 9 Maintenance Chapter contents 9 1 Maintenance on page 66 Maintenance 65...
Page 76: ...76...
Page 80: ...80...
Page 104: ...Owner notes...
Page 105: ...Owner notes...
Page 106: ...Owner notes...
Page 107: ......