4.1 General cabling guidance
Cable types and length
It is important to use cables of the appropriate type
and length
• Unless otherwise stated use only standard cables
of the correct type, supplied by Raymarine.
• Ensure that any non-Raymarine cables are of the
correct quality and gauge. For example, longer
power cable runs may require larger wire gauges
to minimize voltage drop along the run.
Routing cables
Cables must be routed correctly, to maximize
performance and prolong cable life.
• Do NOT bend cables excessively. Wherever
possible, ensure a minimum bend diameter of 200
mm (8 in) / minimum bend radius of 100 mm (4 in).
100 mm (4 in)
200 mm (8 in)
• Protect all cables from physical damage and
exposure to heat. Use trunking or conduit where
possible. Do NOT run cables through bilges or
doorways, or close to moving or hot objects.
• Secure cables in place using tie-wraps or lacing
twine. Coil any extra cable and tie it out of the way.
• Where a cable passes through an exposed
bulkhead or deckhead, use a suitable watertight
feed-through.
• Do NOT run cables near to engines or fluorescent
lights.
Always route data cables as far away as possible
from:
• other equipment and cables,
• high current carrying AC and DC power lines,
• antennae.
Caution: Pulling cables
Do NOT use cords or ropes, attached
to cable connectors, to pull cables
through restricted apertures (e.g. as in
bulkheads), as this could cause damage
to cables.
Strain relief
Ensure adequate strain relief is provided. Protect
connectors from strain and ensure they will not pull
out under extreme sea conditions.
Cable shielding
Ensure that all data cables are properly shielded
that the cable shielding is intact (e.g. hasn’t been
scraped off by being squeezed through a tight area).
4.2 Connections overview
Use the following information to help you identify the
connections on your product.
Connector
Qty
Connects to:
Suitable cables
2
1.
SeaTalk
ng
backbone
2.
NMEA 2000
backbone
3.
SeaTalk
backbone
1.
SeaTalk
ng
spur cables
2.
SeaTalk
ng
to
DeviceNet
adaptor
cable
(A06045)
3.
SeaTalk
to
SeaTalk
ng
adaptor
cable
(A06073)
Connecting SeaTalk
ng®
cables
D12615-2
1. Rotate the locking collar on the unit to the
unlocked position.
2. Ensure the cable’s connector is correctly oriented.
3. Fully insert the cable connector.
4. Rotate locking collar clockwise (2 clicks) until it is
in the locked position.
SeaTalk
ng®
product loading
The number of products that can be connected
to a
SeaTalk
ng
backbone depends on the power
consumption of each product and the physical overall
length of the backbone.
SeaTalk
ng
products have a Load Equivalency
Number (LEN), which indicates the product’s power
consumption. The LEN for each product can be
found in the product’s Technical Specification.
22
p70 / p70R
Summary of Contents for P70
Page 2: ......
Page 4: ......
Page 10: ...10 p70 p70R ...
Page 14: ...14 p70 p70R ...
Page 28: ...28 p70 p70R ...
Page 29: ...Chapter 5 Installation Chapter contents 5 1 Mounting on page 30 Installation 29 ...
Page 38: ...38 p70 p70R ...
Page 48: ...48 p70 p70R ...
Page 58: ...58 p70 p70R ...
Page 68: ...68 p70 p70R ...
Page 74: ...74 p70 p70R ...
Page 80: ...80 p70 p70R ...
Page 94: ...94 p70 p70R ...
Page 110: ...110 p70 p70R ...
Page 118: ...118 p70 p70R ...
Page 121: ......