23.4 Radar troubleshooting
No connection can be made to the scanner
Possible Causes
Possible Solution
Radar powered down
• If the scanner product has shut down, power it up by opening
the Radar app and selecting the
Power
icon.
• A Quantum Radar will shut down after 30 minutes if neither a
wired (RayNet) , nor a wireless (Wi-Fi) connection can be made
to a MFD.
Radar not transmitting
• Select
Transmit
for the relevant Radar scanner from the Radar
app.
Missing or incorrect Wi-Fi
credentials
• If using a wireless (Wi-Fi) connection, check that you have
entered the correct SSID and passcode for your Radar. Both
the SSID and passcode are provided on the Radar scanner’s
packaging, and are also shown on the serial number label on
the underside of the product.
Damaged or disconnected
Power cable / RayNet cable
1.
Check that the cable connectors are fully inserted and locked
in position.
2. Check the power supply cable and connectors for signs of
damage or corrosion, replace if necessary.
3.
With the product turned on, try flexing the cable near to
the display connector to see if this causes the product to
re-boot/loose power, replace if necessary.
4.
Check the vessel’s battery voltage, the condition of the battery
terminals and power supply cables, ensuring connections are
secure, clean and free from corrosion, replace if necessary.
5. With the product under load, using a multi-meter, check for
high voltage drop across all connectors/fuses etc (this can
cause the product to reset/turn off), replace if necessary.
6. Check condition of relevant breakers and fuses, replace
if necessary. If the breaker keeps tripping or fuses keep
blowing, contact a Raymarine authorized dealer for assistance.
Open Array power in Off
position
• Ensure Open Array power switch is in the On position.
Software mismatch between
equipment may prevent
communication
• Ensure all Raymarine products contain the latest
available software, check the Raymarine website:
for software compatibility.
Poor image quality
Possible Causes
Possible Solution
High network bandwidth
usage may interfere with a
Quantum Radar connected
wirelessly
• Disconnect Wireless display and close the Wireless display
page.
• Disconnect other devices connected wirelessly.
Displayed bearing is different to the true bearing
Possible Causes
Possible Solution
Bearing alignment adjustment
required
• Carry out the Bearing Alignment procedure.
Radar will not initialize (Voltage control module (VCM) stuck in “sleep mode”
Possible Causes
Possible Solution
Intermittent or poor power
connection
Check power connection at VCM. (Voltage at input = 12 / 24 V,
Voltage at output = 40 V)
409
Summary of Contents for LIGHTHOUSE 3
Page 2: ......
Page 4: ......
Page 18: ...18 ...
Page 58: ...58 ...
Page 94: ...94 ...
Page 110: ...110 ...
Page 226: ...226 ...
Page 254: ...254 ...
Page 302: ...302 ...
Page 316: ...316 ...
Page 420: ...420 ...
Page 438: ......
Page 448: ......
Page 449: ......