Important:
(1)Step only applicable to iTC-5.
4. Select
Wind Xdcr Adjust
.
5. Use the
Up
and
Down
buttons to adjust the offset value so that the reported AWA is 0 degrees.
6. Select
Select
.
Adjusting apparent wind speed
Adjusting the Apparent Wind Speed (AWS) reading compensates for any small errors which may exist
in the apparent wind speed reading.
Prerequisites:
• To apply an offset to your AWS readings an accurate reference for AWS must be used to compare
the instrument’s AWS reading against.
• Conditions should be calm (i.e. a slight sea) and a steady breeze. Try to ensure the vessel is not
rolling or pitching too much.
From the list of transducers found:
1. Select the device that the transducer you are calibrating is connected to.
A list of available transducer data is displayed.
2.
(1)
Select
Wind
.
Important:
(1)Step only applicable to iTC-5.
3. Select
App Wind Speed
.
The AWS calibration factor page is displayed.