3. Use the
Up
and
Down
buttons to select the desired speed that you want to add a Calibration
point for.
4. Select
Next
.
5. Use the
Up
and
Down
buttons to adjust the Calibration factor to the correct value.
6. Select
Done
.
7. Select
Add
to add the next Calibration point.
8. Repeat steps 3 to 7 for all Calibration points you want to add.
9. Select
Finish
when all Calibration points have been added.
10. Select
OK
.
Calibrating Water temperature
The Water temperature reading can be calibrated as follows:
You will need an suitable thermometer to measure the temperature of the water.
From a favorite page:
1. Press the
Menu
button.
2. Select
Set-up
.
3. Select
Transducers Set-up
.
4. Select
Continue
.
The display will search for and show a list of connected devices. (i.e. iTC-5, DST or transducer
pod)
5. Select the device that the transducer you are calibrating is connected to.
A list of available transducer data is displayed.
6.
(1)
Select
Speed
.
Important:
(1)Step only applicable to iTC-5.
7. Select
Current Temperature
option.
8. Use a suitable thermometer to measure the actual water temperature.
9. Use the
Up
and
Down
buttons to match the displayed Water temperature to the actual measured
water temperature.
10. Select
Save
to save the reading.
4.4 Wind calibration
Calibrating wind
Calibration of wind transducers is important to ensure accurate data is displayed.
Prerequisites:
• You will need to be underway, with sufficient space to turn in a large slow circle unhindered.
34
Summary of Contents for i70
Page 2: ......
Page 4: ......
Page 14: ...14...
Page 53: ...Chapter 6 Data quick view Chapter contents 6 1 Data quick view on page 54 Data quick view 53...
Page 64: ...64...
Page 70: ...70...
Page 78: ...78...
Page 94: ...94...
Page 97: ......
Page 98: ......
Page 101: ...Wind speed units 82...
Page 102: ......
Page 103: ......