Depth
The
Depth
menu provides transducer details and calibration settings. The following options are
available:
•
Details
— The details menu displays information about the installed transducer or interface such as
serial number and software version etc.
•
Depth Offset
— The depth offset menu allows you to configure the location depth readings are
taken from and specify the distance the location is from the transducer face. For depth calibration
details refer to:
Speed
The
Speed
menu enables set-up and calibration of speed transducers. The following options are
available:
•
Details
— The details menu displays information about the installed transducer or interface such as
serial number and software version etc.
•
Speed calibration
— The speed calibration menu provides options for calibrating your speed
transducer. For speed calibration details refer to:
•
Calibrate water temperature
— Enter a temperature offset so that the displayed reading
matches manually taken water temperature. For water temperature calibration details refer to:
p.34 — Calibrating Water temperature
Wind
The
Wind
menu enables set-up and calibration of wind transducers. The following options are
available:
•
Details
— The details menu displays information about the installed transducer or interface such as
serial number and software version etc.
•
Calibrate vane
— Access the wind calibration wizard. For wind calibration details refer to:
•
App wind speed calibration
— Enter an AWS offset value so that the displayed reading matches
an accurate wind speed reference.
DST800 / DST810
The
DST800
/
DST810
menu enables set-up and calibration of compatible DST (Depth, Speed, and
Temperature) smart transducers. The following calibration options are available:
•
Details
— The details menu displays information about the installed transducer or interface such as
serial number and software version etc.
•
Depth offset
— The depth offset menu allows you to configure the location depth readings are
taken from and specify the distance the location is from the transducer face. For depth calibration
details refer to:
•
Speed calibration
— The speed calibration menu provides options for calibrating your speed
transducer. For speed calibration details refer to:
•
Temperature offset
— Enter a temperature offset so that the displayed reading matches
manually taken water temperature. For water temperature calibration details refer to:
p.34 — Calibrating Water temperature
DT800 / DT810
The
DT800
/
DT810
menu enables set-up and calibration of compatible DT (Depth and Temperature)
smart transducers. The following calibration options are available:
•
Details
— The details menu displays information about the installed transducer or interface such as
serial number and software version etc.
•
Depth offset
— The depth offset menu allows you to configure the location depth readings are
taken from and specify the distance the location is from the transducer face. For depth calibration
details refer to:
•
Temperature offset
— Enter a temperature offset so that the displayed reading matches
manually taken water temperature. For water temperature calibration details refer to:
p.34 — Calibrating Water temperature
81
Summary of Contents for i70
Page 2: ......
Page 4: ......
Page 14: ...14...
Page 53: ...Chapter 6 Data quick view Chapter contents 6 1 Data quick view on page 54 Data quick view 53...
Page 64: ...64...
Page 70: ...70...
Page 78: ...78...
Page 94: ...94...
Page 97: ......
Page 98: ......
Page 101: ...Wind speed units 82...
Page 102: ......
Page 103: ......