7.4 Dealer calibration
The dealer calibration procedures include:
• User calibration menu access On (default) and Off.
• Display Response for wind angle readings —
Dictates the rate at which the instrument display
responds to changes in wind angle data.
• Display Response for wind speed readings —
Dictates the rate at which the instrument display
responds to changes in wind speed data.
• Display Response for VMG readings — Dictates
the rate at which the instrument display responds
to changes in VMG data.
• * Boat show mode On and Off (default) (Boat
show mode is only available on displays set as
repeaters).
• Reset to factory defaults.
Note:
Not available on the i60 CH wind instrument.
Setting access to the User Calibration
Menu - i60
During normal operation:
1. Press and hold the
Display
and
True / App
buttons at the same time for approximately 14
seconds, until the
Dealer Calibration
page is
displayed.
2. Press the
VMG
and
Tack
buttons at the same
time to display the
User Calibration Menu
Access
page.
CAL
3. Use the
VMG
or
Tack
buttons to switch access to
the
User Calibration Menu
On and Off.
•
UC1 (default)
— User Calibration menu
enabled
•
UC0
— User Calibration menu disabled
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Display
and
True/App
buttons at the same time for approximately 2
seconds.
Setting the response delay for Wind
Angle readings
During normal operation:
1. Press and hold the
Display
and
True / App
buttons at the same time for approximately 14
seconds, until the
Dealer Calibration
page is
displayed.
2. Press the
VMG
and
Tack
buttons at the same
time to display the
User Calibration Menu
Access
page.
CAL
3. Press the
Display
button until the
Wind Angle
Response
page is displayed (1 press from the
User Calibration Access Menu
page).
4. Use the
VMG
and
Tack
buttons to set the
required level for Wind Angle Response.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Display
and
True/App
buttons at the same time for approximately 2
seconds.
Setting the response delay for Wind
Speed readings
During normal operation:
1. Press and hold the
Display
and
True / App
buttons at the same time for approximately 14
seconds, until the
Dealer Calibration
page is
displayed.
2. Press the
VMG
and
Tack
buttons at the same
time to display the
User Calibration Menu
Access
page.
CAL
3. Press the
Display
button until the
Wind Speed
Response
page is displayed (2 presses from the
User Calibration Access Menu
page).
4. Use the
VMG
and
Tack
buttons to set the
required level for Wind Speed Response.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Display
and
True/App
buttons at the same time for approximately 2
seconds.
40