7.2 Intermediate calibration
Intermediate calibration allows you to:
• Check instrument software version
• * Check the instrument status (either master or
repeater)
Note:
* Not available on i60 CH Wind.
1
0
15
20
25
30
35
40
45
50
55
60 5
4
+
D12492-2
CAL
CAL
Disp
lay
Disp
lay
T
rue /App
Checking the software version and
instrument status
You can check the instrument display’s software
version and status by following the steps below.
Note:
The i60 CH Wind instrument is a repeater
display. You cannot check or change the
instrument status of an i60 CH Wind display
From the software version page:
1
0
15
20
25
30
35
40
45
50
55
60 5
4
+
D12492-2
CAL
CAL
Disp
lay
Disp
lay
T
rue /App
During normal operation:
1. Press and hold the
Display
and
True / App
buttons at the same time for approximately 4
seconds , until the Software Version page is
displayed.
2. Press the
Display
button to show the Instrument
Status page.
The instrument status is displayed (
r 0
= master
and
r 1
= repeater).
Note:
The Software Version and Instrument Status
pages are temporary pages and will time-out
automatically after 8 seconds of inactivity.
7.3 Dealer calibration
The dealer calibration procedures include:
• User calibration menu access On (default) and Off.
• Display Response for wind angle readings —
Dictates the rate at which the instrument display
responds to changes in wind angle data.
• Display Response for wind speed readings —
Dictates the rate at which the instrument display
responds to changes in wind speed data.
• Display Response for VMG readings — Dictates
the rate at which the instrument display responds
to changes in VMG data.
• * Boat show mode On and Off (default) (Boat
show mode is only available on displays set as
repeaters).
• Reset to factory defaults.
Note:
Not available on the i60 CH wind instrument.
Accessing the Dealer Calibration Menu - i60
During normal operation:
1. Press and hold the
Display
and
True / App
buttons at the same time for approximately 14
seconds, until the
Dealer Calibration
page is
displayed.
1
0
15
20
25
30
35
40
45
50
55
60 5
14
+
D12493-2
CAL
Disp
lay
T
rue /App
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Display
and
True/App
buttons at the same time for approximately 2
seconds.
Setting access to the User Calibration Menu
- i60
From the
Dealer Calibration
page:
1. Press the
VMG
and
Tack
buttons at the same
time to display the
User Calibration Menu
Access
page.
+
D12494-2
CAL
CAL
V
MG
T
a ck
2. Use the
VMG
or
Tack
buttons to switch access to
the
User Calibration Menu
On and Off.
•
UC1 (default)
— User Calibration menu
enabled
•
UC0
— User Calibration menu disabled
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Display
and
True/App
buttons at the same time for approximately 2
seconds.
Setting the response delay for Wind Angle
readings
From the
User Calibration Menu Access
page:
Calibration
39
Summary of Contents for i60 ch wind
Page 2: ......
Page 4: ......
Page 6: ...6 i60...
Page 10: ...10 i60...
Page 14: ...14 i60...
Page 22: ...22 i60...
Page 32: ...32 i60...
Page 36: ...36 i60...
Page 42: ...42 i60...
Page 47: ...Chapter 9 Alarms Chapter contents 9 1 Alarms on page 48 Alarms 47...
Page 58: ...58 i60...
Page 66: ...66 i60...
Page 68: ...68 i60...
Page 69: ......
Page 70: ...www raymarine com...