Chapter 6: Installation
111
To connect the display unit to the SeaTalk bus, connect a standard
SeaTalk cable between the SeaTalk connector on the rear of the display
and a SeaTalk instrument or the SeaTalk bus.
Standard SeaTalk cables are available in a range of lengths (part
numbers W284 to W287), and cables for connecting to older SeaTalk
units are also available (part numbers D187 or D188).
NMEA Output to External Navaids
The NMEA Output cable should be connected to the upper, left
connector on the rear of the display unit.
Note: The NMEA Output cable is fitted with a ferrite clamp to ensure
EMC conformance.
Note: The display unit does not supply power via the connector.
A separate power connection to your NMEA units is required.
Power and NMEA Input Connection
The DC power and NMEA input should be connected at the rear Power/
NMEA J5 seven-pin connector. The connector (viewed from the outside)
and pin functions are shown in the following diagram and table.
2
1
4
3
5
7
6
Pin No.
Function
Colour
1
Channel 1 NMEA data input (+ve)
Orange
2
Channel 1 NMEA return (-ve)
Yellow
3
Battery negative
Black
4
Screen (drain wire)
No insulation
5
Battery positive (10.7 - 32 VDC)
Red
6
Channel 2 NMEA data input (+ve)
Green
7
Channel 2 NMEA return (-ve)
Blue
Display Unit
Connections
Summary of Contents for HSB Chartplotter
Page 2: ...HSB Series Chartplotter owner s handbook Document number 81150_1 Date 18th September 1998...
Page 3: ......
Page 7: ...HSB Series Chartplotter iv...
Page 15: ...HSBSeriesChartplotter xii...
Page 46: ...Chapter2 GettingStarted 31...
Page 47: ...32 HSBSeriesChartplotter...
Page 57: ...42 HSBSeriesChartplotter...
Page 133: ...116 HSBSeriesChartplotter...
Page 139: ...122 HSB Series Chartplotter...
Page 154: ......