106
HSB Series Chartplotter
power source and the connector block, and then select the wire size
indicated by the distance following table.
Maximum Extension Power Cable Lengths (m), 12V Systems
Inter-Unit Cable(s)
Power Cable Core
mm
2
: 1.5
2.0
2.5
4.0
6.0
10.0
AWG: 16
15
14
12
10
8
Maximum extension
11.0
15.0
20.0
30.0
45.0
70.0
6.6 Mounting the Display Unit
The display unit can be mounted using the trunnion (yoke) bracket
already fitted, or console mounted using the optional flush-mounting kit
(see section 6.2).
Trunnion (Yoke) Mounting
The display unit can be conveniently mounted on a dash area, chart
table, bulkhead or deckhead, as shown in the following diagram.
1. Loosen the trunnion knobs and remove the trunnion from the display
unit.
2. Mark the locations of the trunnion screw holes on the mounting
surface.
3. Use the screws supplied to fix the trunnion at the marked locations.
4. Fit the display unit to the trunnion, adjust the display angle and
tighten the knobs.
Trunnion
Mounting