Video output resolutions
2 x DVI video outputs (or VGA with
adaptor cable), both of which support
the following resolutions:
• 1024 X 768
• 1280 X 720
• 1280 X 768
• 1280 X 800
• 1280 X 1024
SeaTalk / alarm power output
250 mA at 12 V
Video output
DVI (quantity: 2). Optional VGA
adaptor available.
Audio output
Stereo line out (rated 1 V RMS)
Conformance
• 89/336/EEC as amended by
92/31/EEC
• EN60945:2002
10.2 GVM400 video module
Technical specification
Nominal supply voltage
12 or 24 V dc
Operating voltage range
10.7 to 32 V dc
Fuse / Breakers
12 V supply:
• 2 A fuse protection at distribution
panel.
• 1.2 A thermal circuit breaker
protection at distribution panel.
24 V supply:
• 1 A fuse protection at distribution
panel.
• 1 A thermal circuit breaker
protection at distribution panel.
Typical power consumption
• 650 mA at 12 V
• 330 mA at 24 V
Environmental
Installation environment
• Operating temperature: -15 ºC to
+55 ºC (5 ºF to 131 ºF)
• Non-operating temperature: -25 ºC
to +70 ºC (–13 ºF to 158 ºF)
• Relative humidity limit: 80%
• Water protection: drip resistant
when mounted vertically.
Technical specification
149
Summary of Contents for G-Series system
Page 1: ...G Series system Installation instructions...
Page 2: ......
Page 4: ......
Page 8: ...8 G Series installation instructions...
Page 14: ...14 G Series installation instructions...
Page 98: ...98 G Series installation instructions...
Page 124: ...124 G Series installation instructions...
Page 142: ...142 G Series installation instructions...
Page 146: ...146 G Series installation instructions...
Page 158: ...158 G Series installation instructions...
Page 180: ...www raymarine com...