10.1 GPM processor unit
Technical specification
Nominal supply voltage
12 or 24 V dc
Operating voltage range
10.7 to 32 V dc
Fuse / Breakers
12 V supply:
• 10 A fuse protection at distribution
panel.
• 10 A thermal circuit breaker
protection at distribution panel.
24 V supply:
• 4 A fuse protection at distribution
panel.
• 10 A thermal circuit breaker
protection at distribution panel.
Typical power consumption
No external loads:
• 3 A at 12 V
• 1.5 A at 24 V
With external loads:
• 5 A at 12 V
• 2.5 A at 24 V
Environmental
Installation environment
• Operating temperature: -15 ºC to
+55 ºC (5 ºF to 131 ºF)
• Non-operating temperature: -25 ºC
to +70 ºC (–13 ºF to 158 ºF)
• Relative humidity limit: 80%
• Water protection: drip resistant
when mounted vertically.
Storage conditions for packaged unit
• Temperature: -25 ºC to +55 ºC
(–13 ºF to 131 ºF)
• Relative humidity: 75%
Dimensions
• Width: 335 mm (13.19 in)
• Height: 230 mm (9.06 in)
• Depth: 125 mm (4.92 in)
Weight
6.5 kg (14.33 lb)
Data connections
• NMEA 0183 ports (quantity: 2):
• SeaTalk
• SeaTalk
hs
• SeaTalk
ng
• Compact Flash
• USB (software upgrade only)
148
G-Series installation instructions
Summary of Contents for G-Series system
Page 1: ...G Series system Installation instructions...
Page 2: ......
Page 4: ......
Page 8: ...8 G Series installation instructions...
Page 14: ...14 G Series installation instructions...
Page 98: ...98 G Series installation instructions...
Page 124: ...124 G Series installation instructions...
Page 142: ...142 G Series installation instructions...
Page 146: ...146 G Series installation instructions...
Page 158: ...158 G Series installation instructions...
Page 180: ...www raymarine com...