9.2 Technical specification — ACU-100, ACU-150
ACU-100
ACU-150
Drive current output
• Maximum continuous 7 A at supply
voltage.
• Maximum continuous 12 A at supply
voltage.
Drive clutch output
No clutch connection.
No clutch connection.
Connections
• Rudder reference sensor.
• Power.
• Drive motor.
• Ground.
• Rudder reference sensor.
• Power.
• Drive motor.
• Ground.
Nominal supply voltage
12 V
12 V
Operating voltage range
10.8 V to 15.6 V dc
10.8 V to 15.6 V dc
Power consumption (standby) — main
power supply
300 mA (12 V)
300 mA (12 V)
Power consumption (standby) —
SeaTalkng® power supply
No power supply to SeaTalkng®
No power supply to SeaTalkng®
SeaTalkng® LEN (Load Equivalency
Number)
1
1
SeaTalkng® Power out
No power supply to SeaTalkng®
No power supply to SeaTalkng®
Data connections
SeaTalkng®
SeaTalkng®
Environmental
Installation environment
• Operating temperature: -20 ºC to
+55 ºC (-4 ºF to +131 ºF).
• Storage temperature: -30 ºC to +70 ºC
(-22°F to +158°F).
• Relative humidity: max 93%.
• Waterproof rating:
• Connector panel: IPX2
• Drive electronics: IPX6
Installation environment
• Operating temperature: -20 ºC to
+55 ºC (-4 ºF to +131 ºF).
• Storage temperature: -30 ºC to +70 ºC
(-22°F to +158°F).
• Relative humidity: max 93%.
• Waterproof rating:
• Connector panel: IPX2
• Drive electronics: IPX6
Dimensions
• Width: 180 mm (7.1 in).
• Height: 140 mm (5.5 in).
• Depth: 52 mm (2.0 in).
• Width: 180 mm (7.1 in).
• Height: 140 mm (5.5 in).
• Depth: 52 mm (2.0 in).
Weight
0.6 kg (1.32 lbs).
0.6 kg (1.32 lbs).
EMC compliance
• Europe: 2004/108/EC.
• Australia and New Zealand: C-Tick, Compliance Level 2.
67