2.6 Multifunction display connections
You can connect your AIS unit to a multifunction display using either
the dedicated SeaTalk
ng
connector or NMEA0183 (high baud rate)
via the power/data cable.
Follow the steps shown in either:
• Connecting NMEA0183 (high baud rate, or
• Connecting using SeaTalk
ng
Note:
Do not connect your multifunction display using both
NMEA0183 and SeaTalk
ng
at the same time as this will cause
data conflicts.
Connecting NMEA0183 (high baud rate)
If your multifunction displays are NOT connected to a SeaTalk
ng
system, connect the AIS unit’s 38400 baud, NMEA0183 bus to your
multifunction display’s 38400 baud, NMEA0183 wires.
1. Identify the 38400 baud, NMEA0183 wires on the AIS units
power/data cable.
2. Identify the 38400 baud, NMEA0183 wires on your multifunction
display.
3. Connect the wires as shown below.
NMEA0183 (high baud rate)
Item
AIS wire
color
AIS signal
Multifunc-
tion display
wire color
Multifunc-
tion display
signal
1.
Green
IN –
Orange and
brown
OUT –
2.
White
IN +
Orange and
yellow
OUT +
3.
Blue
OUT –
Orange and
green
IN –
4.
Brown
OUT +
Orange and
white
IN +
22
AIS350 / AIS650 Installation instructions