11.1 Power options
This product must be powered using ONE of the following methods:
1.
PoE (Power over Ethernet)
— Either:
• Direct connection to a PSE (Power Sourcing Equipment). Only one
cable is required to carry both data and power signals.
• Connection to a suitably-powered PoE injector or PoE network switch.
Only one cable is required to carry both data and power signals
between the camera and the PoE injector. However, the PoE injector
itself will require its own power source, and a separate ethernet
network cable to a PC, Raymarine® multifunction display or Raymarine®
network switch. The PoE injector method is useful if the camera is
located a long distance from a power source.
2.
Self-powered
• Direct connection to a vessel's power supply using the supplied power
cable. With the direct connection method, a separate ethernet network
cable is required when connecting to a PC, Raymarine® multifunction
display or Raymarine® network switch.
Warning: Powering PoE devices
PoE devices can be powered via an ethernet connection (PoE)
OR via a dedicated power cable.
NEVER connect a PoE device’s dedicated power cable when it
is being supplied PoE.
When the PoE device’s dedicated power cable is not
connected, any bare end wire connections must be separately
covered with insulation.
Warning: 12 Volt dc only
This product must ONLY be connected to a
12 V dc
power
source.
11.2 Dedicated power connection
The unit can be powered from a
12 V dc
power supply using its dedicated
power cable.
1.
CAM300.
2. RJ45 to RJ45 waterproof coupler (4115028 —
not supplied
).
3.
RJ45 (male) to RayNet (female) adapter cable (A62360 —
not supplied
).
DO NOT CONNECT
to a PSE (Power sourcing Equipment) if the camera
is being supplied power via the dedicated power cable.
4.
A waterproof fuse holder containing a suitably-rated in-line fuse
must
be
fitted (
not supplied
) — see below for fuse ratings.
5. 12 V dc power supply providing power to the camera.
Inline fuse and thermal breaker ratings
The following inline fuse and thermal breaker ratings apply to your product:
Inline fuse rating
Thermal breaker rating
250 mA
3 A
Important:
The suitable fuse rating for the thermal breaker is dependent on the
number of devices you are connecting. If in doubt consult an authorized
Raymarine® dealer.
11.3 Grounding not required
This product is fully insulated and does NOT require separate grounding.
39