Note:
• Axiom Pro MFDs are supplied with a power cable that has a straight connector.
• Axiom XL MFDs are supplied with a power cable that has a right-angled connector.
1.
Power/Video/NMEA 0183 cable connects to the rear of the MFD.
2. Positive (Red) wire connects to battery positive (+) terminal.
3.
Inline fuse. For suitable fuse ratings, refer to:
In-line fuse and thermal breaker ratings
.
4.
Negative wire connects to the battery’s negative (-) terminal.
5. Ground wire connects to RF ground point. If no ground point is available connect to the battery
negative (-) terminal.
In-line fuse and thermal breaker ratings
The following in-line fuse and thermal breaker ratings apply to your product:
In-line fuse rating
Thermal breaker rating
15 A
15 A (if only connecting one device)
Note:
• The suitable fuse rating for the thermal breaker is dependent on the number of devices you are
connecting. If in doubt consult an authorized Raymarine dealer.
• Your product’s power cable may have a fitted in-line fuse. If not, you must fit an in-line fuse to the
positive wire of your product’s power connection.
Caution: Power supply protection
When installing this product ensure the power source is adequately protected by
means of a suitably-rated fuse or thermal circuit breaker.
Power distribution
Recommendations and best practice.
• The product is supplied with a power cable, either as a separate item or a captive cable
permanently attached to the product. Only use the power cable supplied with the product. Do
NOT use a power cable designed for, or supplied with, a different product.
• Refer to the
Power connection
section for more information on how to identify the wires in your
product’s power cable, and where to connect them.
• See below for more information on implementation for some common power distribution scenarios: