Possible causes
Possible solutions
Damaged cables
1.
Check the unit’s connector for broken or bent pins.
2. Check that the cable connector is fully inserted into the
unit and that the locking collar is in the locked position.
3.
Check the cable and connectors for signs of damage or
corrosion, replace if necessary.
4.
With the unit turned on, try flexing the power cable near
to the display connector to see if this causes the unit to
re-boot/loose power, replace if necessary.
5. Check the vessel’s battery voltage, the condition of the
battery terminals and power supply cables, ensuring
connections are secure, clean and free from corrosion,
replace if necessary.
6. With the product under load, using a multi-meter, check
for high voltage drop across all connectors/fuses etc (this
can cause the Sonar applications to stop scrolling or the
unit to reset/turn off), replace if necessary.
Vessel speed too high
Slow vessel speed and recheck.
Bottom too shallow or too deep
The bottom depth may be outside of the transducers depth
range, move vessel to shallower or deeper waters as relevant
and recheck.
Poor / problematic image
Possible causes
Possible solutions
Vessel stationary
Fish arches are not displayed if the vessel is stationary; fish
will appear on the display as straight lines.
Scrolling paused or speed set too
low
Unpause or increase sonar scrolling speed.
Sensitivity settings may be
inappropriate for present
conditions.
Check and adjust sensitivity settings or perform a Sonar reset.
Damaged cables
1.
Check the unit’s connector for broken or bent pins.
2. Check that the cable connector is fully inserted into the
unit and that the locking collar is in the locked position.
3.
Check the cable and connectors for signs of damage or
corrosion, replace if necessary.
4.
With the unit turned on, try flexing the power cable near
to the display connector to see if this causes the unit to
re-boot/loose power, replace if necessary.
5. Check the vessel’s battery voltage, the condition of the
battery terminals and power supply cables, ensuring
connections are secure, clean and free from corrosion,
replace if necessary.
6. With the product under load, using a multi-meter, check
for high voltage drop across all connectors/fuses etc (this
can cause the Sonar applications to stop scrolling or the
unit to reset/turn off), replace if necessary.
60
Summary of Contents for axiom pro 9 RVX
Page 2: ......
Page 4: ......
Page 8: ...8...
Page 12: ...12...
Page 32: ...32...
Page 50: ...50...
Page 54: ...54...
Page 76: ...76...
Page 86: ......
Page 87: ......
Page 165: ......
Page 170: ......
Page 178: ...12...
Page 214: ...48...
Page 222: ...56...
Page 228: ...62...
Page 272: ...106...
Page 296: ...130...
Page 302: ...136...
Page 310: ...144...
Page 320: ...154...
Page 344: ...178...
Page 354: ......
Page 358: ......
Page 359: ......