10.1 NMEA 2000 / SeaTalkng connection
The display can be connected to a NMEA 2000 / SeaTalkng ® network by
connecting a spur cable to the
NMEA 2000
(DeviceNet) connector located
on the rear of the display.
1.
Display’s
NMEA 2000
(DeviceNet) connector.
2. Use the supplied DeviceNet to SeaTalkng ® adaptor cable to connect to
a SeaTalkng ® network backbone.
3.
Alternatively you can connect to a NMEA 2000 backbone using a
standard DeviceNet cable (not supplied).
Note:
1.
SeaTalkng ® and NMEA 2000 devices must be connected to a correctly
terminated backbone.
2. SeaTalkng ® and NMEA 2000 devices can not be connected directly
to the display.
3.
Refer to the instructions supplied with your SeaTalkng ® or NMEA 2000
device for details on creating a backbone.
Refer to
for a list of available SeaTalkng ®
cables.
10.2 NMEA 0183 connection
The display can transmit and receive NMEA 0183 data when using a
compatible NMEA 2000 to NMEA 0183 converter, such as the Actisense®
NGW-1 converter (part number: A80721), connected to the same
[NMEA 2000]
/ SeaTalkng ® network as the display.
Important:
Ensure all devices are powered off before making connections.
Connect the converter to your NMEA 2000 or SeaTalkng ® network, using
either a DeviceNet to SeaTalkng ® adaptor cable, or a DeviceNet cable as
appropriate. Then, connect the converter’s NMEA 0183 bare wires to the
relevant wires on your NMEA 0183 device, and crimp and insulate the wires.
Note:
The details below are provided as an example of how to connect a device
using the Actisense® NGW-1 converter (A80721). Depending on your
NMEA 0183 device, you may require a different converter. The converter
and device wire colors may also vary from those shown. Refer to the
instructions supplied with your NMEA 0183 device and your converter to
identify correct signal connections.
45
Summary of Contents for AXIOM 2 XL
Page 2: ......
Page 4: ......
Page 22: ...CHAPTER 5 PRODUCT DIMENSIONS CHAPTER CONTENTS 5 1 Product dimensions page 23 22...
Page 39: ...CHAPTER 9 POWER CONNECTIONS CHAPTER CONTENTS 9 1 Power connection page 40 Power connections 39...
Page 56: ...CHAPTER 13 AUDIO CONNECTIONS CHAPTER CONTENTS 13 1 Audio RCA connections page 57 56...
Page 95: ...RayNet to RJ45 and RJ45 SeaTalkhs adapter cables Spares and accessories 95...
Page 102: ......
Page 107: ......