background image

10

ST30 Round Bidata Owner’s Handbook

• The equipment is supplied from a separate battery from that used for

engine start. Voltage drops below 10 V in the power supply to our
products, and starter motor transients, can cause the equipment to
reset.  This will not damage the equipment, but may cause the loss of
some information and may change the operating mode.

• Raymarine specified cables are used at all times. Cutting and

rejoining these cables can compromise EMC performance and so
must be avoided unless doing so is detailed in the installation
manual.

• If a suppression ferrite is attached to a cable, this ferrite should not

be removed. If the ferrite needs to be removed during installation it
must be reassembled in the same position.

Suppression ferrites

The following illustration shows typical cable suppression ferrites fitted
to Raymarine equipment. Always use the ferrites supplied by
Raymarine.

D3548-2

Connections to Other Equipment

If your Raymarine equipment is to be connected to other equipment
using a cable not supplied by Raymarine, a suppression ferrite MUST
always be fitted to the cable close to the Raymarine unit.

3.2 Installing the instrument

When selecting a location for the Bidata instrument, ensure that:

• It is at least 230 mm (9 in) from a compass

• It is at least 500 mm (20 in) from radio receiving equipment

• There is sufficient clearance behind the bulkhead to house the rear of

the instrument, fixing studs, “C” bracket, and SeaTalk cables.

075_4c03.p65

11/04/01, 11:27

10

Summary of Contents for Autohelm ST30 Bidata

Page 1: ...ST30 Round Bidata Owner s Handbook Document number 81075_4 Date 1stApril2001 075_4cov p65 11 04 01 11 27 1...

Page 2: ...Copyright Raymarine Limited 2001 075_4cov p65 11 04 01 11 27 2...

Page 3: ...neenvironment ThedesignandmanufactureofRaymarineequipmentandaccessories conformtotheappropriateElectromagneticCompatibility EMC standards butcorrectinstallationisrequiredtoensurethatperformance isnotc...

Page 4: ...ii ST30RoundBidataOwner sHandbook 075_4pre p65 11 04 01 11 27 2...

Page 5: ...h 2 Shallow alarm 2 Adjusting shallow depth 2 Silencing the shallow alarms 3 Turning shallow alarm ON and OFF 3 Offset 3 Default display 3 Loss of signal 3 1 3 Speed key functions 4 Speed 4 Trip dista...

Page 6: ...ower via SeaTalk 13 3 5 Adding an independent lighting switch 13 3 6 Installing the Biducer transducer 14 Cable connections 14 3 7 Calibration requirement 14 Chapter 4 Calibration 15 4 1 Introduction...

Page 7: ...ithout saving 19 Default display 20 4 3 Extended calibration 20 Calibration 21 Boat show 21 Depth and speed damping 21 Saving extended calibration 21 Exit extended calibration without saving 21 Specif...

Page 8: ...vi ST30RoundBidataOwner sHandbook 075_4pre p65 11 04 01 11 27 6...

Page 9: ...marineproduct Wearesureyour ST30instrumentwillgiveyoumanyyearsoftrouble freeoperation Thisinstrumentisdesignedtoprovidereliableperformance even underthemostdemandingconditions bidata depth speed depth...

Page 10: ...a transducer is not included If any item is not present contact your Raymarine Dealer If the ST30 Round Bitata is to be flush mounted do not fit a display bezel ST30 Round Bidata instrument Sealing ga...

Page 11: ...onmanysports boats TheBidatausesaneasy to installtransommounttransducer Biducer combiningbothspeedanddepthelementsinasinglehousing IftheBidataisusedinconjunctionwithaSeaTalkautopilot thespeed input pr...

Page 12: ...hedepth feetormetres atwhichpoint audibleandvisualalarmswillbetriggered Thesealarmscanbe silencedbypressingthespeedordepthkey Adjusting shallow depth 1 Fromtheshallowdepthalarmdisplay pressdepthandspe...

Page 13: ...played 2 PressdepthandspeedtogethermomentarilytoenterCAL mode 3 PressdepthtoswitchthealarmONorOFF 4 Press depthandspeedtogetherfor2secondstoexitCALmode Offset Thisisthedistance feetormetres fromtheBid...

Page 14: ...tance Tripisthedistancecoveredbetweenpoweronandpoweroff Thiscan benauticalmiles NM kilometres KM orstatutemiles SM Resetting Trip Distance Pressandholdthe speedkeyuntilthetripdistanceiszeroed distance...

Page 15: ...depth speed depth speed OFF L0 1 second TheBidatahasfourilluminationsettings off low L1 medium L2 and high L3 TheBidataautomaticallyreturnstonormaloperation5secondsafter thelastkeypress Iftheshallowde...

Page 16: ...6 ST30RoundBidataOwner sHandbook 075_4c01 p65 11 04 01 11 27 6...

Page 17: ...rmancefromyourRaymarine equipment guidelinesaregivenintheinstallationinstructions to enableyoutoensureminimuminteractionbetweendifferentitems ofequipment i e ensureoptimumElectromagneticCompatibility...

Page 18: ...breaker fuse No speed information Biducer paddlewheel obstructed Poor Biducer cable connection or cable damaged Nodepthinformation Aerated water boat wakes or propeller wash Normal operation will ret...

Page 19: ...eisnotcompromised Althougheveryefforthasbeentakentoensurethattheywillperform underallconditions itisimportanttounderstandwhatfactorscould affecttheoperationoftheproduct Theguidelinesgivenheredescribet...

Page 20: ...eferriteneedstoberemovedduringinstallationit mustbereassembledinthesameposition Suppression ferrites Thefollowingillustrationshowstypicalcablesuppressionferritesfitted toRaymarineequipment Alwaysuseth...

Page 21: ...esewillnotcauseahazardby weakeningcriticalpartsofthevessel sstructure Ifindoubt seek advicefromareputableboatbuilder 1 Ifappropriate usethetemplateprovidednearthebackofthisbook tomarktheintendedlocati...

Page 22: ...tuds C bracket and thumbnutsasshown D1600 2 bidata depth speed depth speed 3 3 Connecting the power supply direct CAUTION Ensurethatthepowersupplyisprotectedbya5 Afuseorcircuit breaker 1 Plugthe2 m 6...

Page 23: ...ntviathedaisyloomcable asshown 3 5Adding an independent lighting switch WhentheBidataispartofaSeaTalksystemthelightingiscontrolled fromthekeypadorfromanotherSeaTalkinstrumentonthebus Ifyouhaveanindepe...

Page 24: ...vided Cable connections ThecablefromtheBiducerconsistsoffivecoreswhichshouldbe connectedtotheBidataasfollows Cablecolour Bidataconnection Green Green SPEED Screen Grey SPEED Red Red SPEED Blue Blue DE...

Page 25: ...uresmustbecarriedoutbeforetheequipmentisused operationally tooptimisetheperformanceoftheinstrumentwiththe vessel Allkeypressesaremomentaryunlessotherwisestated EMC conformance Alwayschecktheinstallati...

Page 26: ...onproceduretoturnonbasic calibration Offset entry Thisoptionisusedtoselectwhetherthedisplayedwaterdepthisfrom thesurfaceorbelowtheBiducer Seta 0 zero offset togivethedepthfromthetransducertothe seabed...

Page 27: ...abledepthunitsaremetresorfeet Theseunitsaretoggled withthedepthorspeedkey Speed and log units TheavailablespeedandlogunitsareKmh Mph Kts SMandNM Theseunitsaretoggledwiththedepthorspeedkey Log calibrat...

Page 28: ...bytwoto obtaintheaverage 4 AttheLOGcalibrationdisplay pressdepthandspeedtogether momentarilytoentereditmode 5 Enterthecorrectionfactor charteddistancedividedbythe average usingthedepthkeytoincreasethe...

Page 29: ...y asarepeatingunitdisplayingspeedand depthinformationfromanotherinstrument PressspeedtotogglebetweenMASTER R0 andREPEATER R1 operatingmodes Inrepeatermode Youcannotenterbasiccalibration Youcannotviewo...

Page 30: ...ress 4 3 Extended calibration Usethefollowingflowcharttocarryoutextendedcalibration Theextendedcalibrationfeaturesillustratedbelowarecycledusingthe depthkey bidata depth speed depth speed CAL 15 sec C...

Page 31: ...ationprogramfordealeruseonly 1 ONand0 OFF Depth and speed damping Dampingcontrolstherateatwhichthedisplayeddataisupdated The selectablerange adjustedusingthespeedkey isbetween1and15 with1providingarap...

Page 32: ...22 ST30RoundBidataOwner sHandbook 075_4c04 p65 11 04 01 11 27 22...

Page 33: ...res 0 to 400 feet Speedrange 0to99 9knots mph orkph Trip 0to999nm sm orkm Log 0to5999nm sm orkm Shallowalarm 3to33feet 1to10metres Depthoffset 9 9 to 9 9 feet 4 0to 4 0metres Illumination 3levelsviaSe...

Page 34: ...24 ST30RoundBidataOwner sHandbook 075_4spe p65 11 04 01 11 28 24...

Page 35: ...ST30 Round Bidata Template Cut hole to 86 mm 3 8 in diameter max 3 Cut out shaded area only 075_4tem p65 11 04 01 11 28 1...

Page 36: ...075_4tem p65 11 04 01 11 28 2...

Page 37: ...mpellers impeller bearings and impeller shaft are specifically excluded from this Warranty Magnetrons Cathode Ray Tubes CRT TFT Liquid Crystal Displays LCD and cold cathode fluorescentlamps CCFL haile...

Page 38: ...9 Ext 2333 or 1 603 881 5200 Ext 2333 Customer Support Telephone 44 0 23 9271 4713 Fax 44 0 23 9266 1228 Technical Support Telephone 1 800 539 5539 Ext 2444 or 1 603 881 5200 Ext 2444 Email techsuppor...

Reviews: