www.Busse-Yachtshop.de - [email protected]
22
A-Series display - Installation instructions
3.3
Power connection
Grounding
•
Use a dedicated earthing plate (e.g. dynaplate) in contact with
the water.
•
Ground cables may be routed to a common point (e.g. within the
switch panel. With a single (appropriately rated) copper braid
connecting to the earthing plate.
•
Use flat tinned copper braid, 30 A rating (1/4 inch) or greater.
Equivalent stranded wire diameter 4mm or greater.
•
Keep the length of the earth braid as short as possible.
A-Series power cable
A-Series power cable extension
The following restriction applies to any extension to the power cable:
Fuses & circuit protection
WARNING: Grounding
This display is not intended for use on “positive”
ground boats. The power input cable drain wires
must be connected directly to the boats ground.
Data
Ship's ground
D11354-1
PWR/NMEA
SONAR
Chart plotter / Fishfinder
A-Series display
Red +ve
Black -ve
Black drainwire
Cable
Part No
Notes
2 m (6.56 ft)
A50/A57/A70 Power
and NMEA Cable
R62157
Supplied with A-Series unit.
For other cables and accessories refer to
Options and accessories on page 56
.
Length (max)
Cable gauge (AWG)
10m (32.8 ft)
14
Equipment
Thermal
breaker
Fuse
A50, A50D, A57D, A70, A70D
10A
10A
Summary of Contents for A Series A50
Page 10: ...www Busse Yachtshop de info busse yachtshop de 10 A Series display Installation instructions ...
Page 18: ...www Busse Yachtshop de info busse yachtshop de 18 A Series display Installation instructions ...
Page 28: ...www Busse Yachtshop de info busse yachtshop de 28 A Series display Installation instructions ...
Page 46: ...www Busse Yachtshop de info busse yachtshop de 46 A Series display Installation instructions ...
Page 59: ...www Busse Yachtshop de info busse yachtshop de ...