Raycus RFL-P500 User Manual Download Page 18

Wuhan  Raycus  Fiber  Laser  Technologies  Co.,  Ltd. 

User Guide of RFL-P500

 

14

 

 

protective  cover  and  a  lock  catch.  Please  use  the  protective  cover  and 

lock catch when not use the laser device. 

2.

 

POWER:

Air switch. Controlling the on-off of AC. 

3.

 

CTRL-INTERFACE:

  Control  interface.  This  interface  provides  all 

control  signals,  including  RS232  communication,  laser  switch  control, 

laser remote control mode selection, analog control, modulation signal, 

Interlock  interface.  Please  reference  table  4  for  specific  definition  of 

control line. The socket is provided with a protective cover and a lock 

catch. Please use the protective cover and lock catch when not use the 

laser device. 

4.

 

RS-232:

  RS-232  interface.  Provides  remote  control  and  fault 

information storage for lasers. See 4.4.3 for details. 

5.

 

SERVICE:

Provide  some  external  functions  for  customers.  See  4.4.1 

Interface Specification for details. 

6.

 

WATER

The  pagoda  typepipe  connector.  The  intake  and  outlet  are 

used for inflow and reflux cooling water. 

4.3

 

Power Connection 

 

CAUTION:

 

a)

 

Before  connect  the  product  to  AC  power,  you  must  check  up 
that  the  AC  supply  you  will  apply  is  in  accordance  with  the 
specifications provided in Table 1. 

b)

 

Failure to correctly connect the cable could damage the device. 
Please  check  whether  the  power  cable  and  the  control  cable  is 
correctly connected before usage. 

 

A power cord is provided in the package, as in Figure 6 

Summary of Contents for RFL-P500

Page 1: ...版本号 密级 内部 A0 会签 阶段 标记 D RFL P500 500W 脉冲光纤激光器 英文说明书 RFL P500 JS02 部 门 脉冲激光器技术研究部 编 写 刘 红 20210225 校 对 帅维文 20210225 审 核 李 科 20210225 标 审 李其军 20210305 批 准 黄 保 20210305 武汉锐科光纤激光技术股份有限公司 朱超 朱泓旭 旧底图登记号 底图登记号 ...

Page 2: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL P500 RFL P500 Pulsed Fiber Laser User Guide Wuhan Raycus Fiber Laser Technologies Co Ltd ...

Page 3: ...5 2 5 Attentions 6 2 6 Specifications 6 3 Installation 7 3 1 Dimensions 7 3 2 Dimensions of Output Head 9 3 3 Cooling Requirements 10 4 Using the Product 12 4 1 Front Panel 12 4 2 Rear Panel 13 4 3 Power Connection 14 4 4 Interface Definitions 15 4 4 1 SERVICE 15 4 4 2Control Interface 16 4 4 3 RS 232 Serial Port 19 5 Application Steps of Laser Device 20 5 1 Pre inspection 20 5 2 Operational Steps...

Page 4: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL P500 7 3 Service and Repair 23 ...

Page 5: ...ean Community standards EN 60825 1 clause 9 this series of lasers are classified as a high power Class 4 This product emits invisible laser radiation at wavelength of 1064 nm and the maximum power is 500W Direct or indirect exposure of high power of laser radiation may cause damage to the eyes or skin Despite the radiation being invisible the beam may cause irreversible damage to the retina and co...

Page 6: ...on Figure 1 Safety identification position Table 1 Safety identification English Label Chinese Lable English Label 500W Chinese Lable 500W English Label Chinese Lable 1 Laser Emit Head 2 Type 4 Laser Product 3 Class 2M Laser Product Label 2mW Red Laser 4 CE Label 5 Electrical Hazard 6 ID Label ...

Page 7: ... AC voltage is supplied normally CAUTION Wrong wiring mode or power supply voltage will cause an un recoverable damage to the laser device 1 6 Other Safety Rules a Do not directly view the laser output head when laser emitting Avoid using the laser in a dark environment b Do not use fiber lasers in dark environments c If this device is used in a manner not specified in this document the protection...

Page 8: ...Applications Laser cleaning Scientific research 2 2 Package Parts Please refer to package accessoriesare in the packing box 2 3 Unpacking and Inspection Raycus fiber laser is delivered in a package which is designed to offer the maximal safety Upon the delivery please inspect all packaging for evidence of mishandling or damage If you find any evidence of mishandling please keep the damaged materia...

Page 9: ...mption W 2500W Installation Environment Flat and no vibration Ambient Temperature 10 40 Relative Humidity 30 70 Weight kg 70kg Note a Make sure the product is properly grounded before use b The laser output head is connected with fiber optic cable Please inspect the output head carefully for dust or other contaminations Use appropriate lens paper to clean it if necessary c Failure to follow the in...

Page 10: ...e sure the opening direction of the cap is put down e Failure to follow the instructions may cause laser power loss such loss is not covered by warranty 2 6 Specifications Table 3 Product Specifications Items Test Condition Value Unit Optical Characteristics Operation Mode Pulse Polarization State Random Output Power RR 10kHz Pmax 200 P 220 W RR 20 50kHz Pmax 500 P 520 W Output Power Tunability 10...

Page 11: ...P 25 mm mrad Divergence Half Angle 0 13 rad Electrical Characteristics Power Supply AC 220V 10 50 60Hz V Max Power Consumption RR 50kHz P 100 10 Pmax 2500 W Control Mode DB25 Other Characteristics Dimensions W H D 502 254 755 mm Weight 70 kg Operating Ambient Temperature 10 40 Humidity 30 70 Storage Temperature 20 60 Cooling Method Water Cooling means customization 3 Installation 3 1 Dimensions Fi...

Page 12: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL P500 8 ...

Page 13: ...utput Head The output head of RFL P500 is QBH the following figure 3 show the details of the QBH output head Figure 3 QBH Output head unit mm CAUTION a Keep the protective cap properly prevent it from contamination Or the aperture will be contaminated when capped b Make sure the aperture and the cavity of the processing head is clean ...

Page 14: ...use 30 alcohol volume ratio and replace it every 2 months 4 If ambient temperature is below 10 the chiller with both heating and cooling functions must be used and keep it in full time operation c Other requirements 1 Before start the device ensure that the flow and return connections are correct connected and confirm that there is no leakage in all the water circuits Any abnormal condition in the...

Page 15: ...60Hz and the earth line is connected make sure it is firm and reliable c Connect the power cable and control cable to the product when power supply is OFF d Clamp the water pipes ontopipe connector run the chiller to check if there is any leakage in the water circulation e Check the output head and clean it before installation This procedure must be performed by Raycus personnel or person authoriz...

Page 16: ...n the product is installed Avoid excessive twisting and tight bends during the robotic arm movements b Tight bends will damage the laser delivery system CAUTION c Keep the protective cap properly prevent it from contamination Or the aperture will be contaminated when capped d Make sure the aperture and the cavity of the processing head is clean 4 Using the Product 4 1 Front Panel Figure 4 shows th...

Page 17: ...s button is pressed down the product is ready to emit laser and the LED illumines Press again will release the button and disable the laser emission 4 ALARM Alarm indicator indicates a fault condition when the yellow LED illumines 5 EMERGENCY STOP Press it down to stop the laser immediately Turn it clockwise to release but the laser cannot start before it s powered on with key switch for a second ...

Page 18: ...use the protective cover and lock catch when not use the laser device 4 RS 232 RS 232 interface Provides remote control and fault information storage for lasers See 4 4 3 for details 5 SERVICE Provide some external functions for customers See 4 4 1 Interface Specification for details 6 WATER The pagoda typepipe connector The intake and outlet are used for inflow and reflux cooling water 4 3 Power ...

Page 19: ...ng After insert it lock it with the lever The other end of the power cord is stripped off labeled L N and PE respectively You should connect the wires to the 220V AC power supply according to the labels L Live Wire N Neutral Wire PE Earth Wire 4 4 Interface Definitions 4 4 1 SERVICE Turn the key anticlockwise to the REM can active the laser in remote control mode WARNING Please pay much attention ...

Page 20: ...9 header If the pins 6 and 7 are disconnected the device will immediately interrupt the light and the Yellow fault alarm lamp will be lit Six and seven legs need to be short jointed before the laser is emitted CAUTION Interlock interface must not access active signal otherwise it will cause interface damage and laser failure 4 4 2Control Interface Figure 8 shows a schematic diagram of the DB25 con...

Page 21: ...al High level turn on low level turn off 20 Sync Pulse Repetition Rate Synchronization input square wave 10KHz 50KHz 22 Guide Laser signal High level turn on low level turn off 23 Safety control signal Lighting is allowed at high level and prohibited at low level Customer Access Safety Door a The pump current of diode laser and the laser output power are controlled by setting the value of PIN1 PIN...

Page 22: ... Signal Definition 12PIN 11PIN 16PIN 21PIN Alarm item X Low Low Low Temperature alarm X High Low Low Power failure X Low Low High Normal X High Low High Device not ready X Low High Low Laser High Reflection Warning X Low High High System failure X High High Low Spare X High High High Spare e Laser warning output signals PIN11 16 21 are all connected with optocouplers and 17 pins 5V power supply is...

Page 23: ...f output signal interface circuit 4 4 3 RS 232 Serial Port Figure 11 shows the RS 232 serial port schematic diagram Figure 11 RS 232 serial port schematic diagram The pins are defined as follows Table 9 RS 232 PIN Description PIN Function Description 2 RXD Laser Data Receiver 3 TXD Laser data transmitter 5 GND Laser data reference Others NC Unconnected in suspension RS232 interface is a special in...

Page 24: ...m whether it can be blown off If not wipe it gently with the lens paper dipped in alcohol and then check it with a special flashlight d Check whether the power supply and control signal of the laser are connected correctly e Check whether the emergency stop switch is loose 5 2 Operational Steps a Start up operation steps Power on the laser turn on the air switch turn on the key switch the key swit...

Page 25: ...so the water connection is correct When the water cooling system works normally and the water temperature drops below 30 C restart the laser If the alarm continues please contact Raycus Low temperature alarm Check whether the actual water temperature of the water is too low In addition a low ambient temperature may also cause a low temperature alarm when the laser is cold Please wait until the wat...

Page 26: ...ants that all Raycus fiber laser products are comformed to applicable product specifications under normal use and are free from defects in materials and work manship The warranties start on the date of shipment from Raycus for a period of time as set forth in the applicable purchase contracts or product specifications Raycus has the right to choose to repair or replace any product that proves to b...

Page 27: ...and Repair Do not open the device There are no user serviceable parts equipment orassemblies for user in this product All service and maintenance shall be performedby qualified Raycus personnel Please contact Raycus as soon as possible when problems under warranty about maintenance happened to the product The product returned with permission should be placed in a suitable container If any damage h...

Reviews: