User’s guide Ytterbium Pulsed Fiber Laser RFL-P200 Ver.: 1.0
14
CAUTION:
The cooling system should be turned on first. Check any
water leakage and make sure that the water temperature reaches the set
point before you start the laser(Summer: 29
±
1
°
C; Winter: 25
±
1
°
C).
3.3
Installation Procedure
(1)
Check if the power supply has the correct voltage (Single-phase 220VAC±10%
,
50/60Hz),
and the earth line is connected, make sure it is firm and reliable;
(2)
Place the product in an appropriate position, immobilize it if necessary;
(3)
Connect the power cable and control cable to the product when power supply is OFF;
(4)
Insert the water pipes into the inlet and outlet;
(5)
Check the output head and clean it if necessary. This procedure must be performed by
Raycus personnel or person authorized by Raycus. Make sure the environment is clean, or
the output head may be contaminated. It is prohibited to use fan during installation, which
will cause dust in the air;
(6)
Prevent the delivery cable from treading, pinching or excessive bending during installation;
CAUTION: All the cables can only be connected when power supply is
off. Hot plug may damage the laser.
CAUTION:
Ensure that there are no fiber bends with radius less than 30cm when the
product is installed. Avoid excessive twisting and tight bends during the
robotic arm movements. Tight bends will damage the laser delivery
system.