User’s guide Ytterbium Pulsed Fiber Laser RFL-P200 Ver.: 1.0
8
(4)
Please inspect the output head carefully for dust or other contaminations. Use appropriate
lens paper to clean it if necessary. Do not touch the output lens at any time;
(5)
Please cap the output head when it is not in use, and make sure the cap is clean;
(6)
It is not allowed to install the output head when the laser is in operation;
(7)
Do not look into the output head directly. Wear appropriate protective eye glasses all the
time when operating the laser;
(8)
Failure to follow the instructions may cause malfunction and damage to the device, such
damage is not covered by warranty.
2.7
Specifications
The specifications are listed in the following table
Table 4: Product Specifications
Model
Test Conditions
Indicator Value Unit
Optical properties
Operation Mode
Pulsed
/
Polarization State
Random
/
Nominal average output power
RR=10kHz Pmax
100
≤
P
≤
110
W
RR=20kHz Pmax
200
≤
P
≤
210
W
RR=30kHz Pmax
200
≤
P
≤
210
W
RR=50kHz Pmax
200
≤
P
≤
210
W
Output Power Tunability
/
10-100
%
Center wavelength
RR=50kHz P=Pmax
1064
±
5
nm
Spectral width
RR=50kHz P=Pmax
≤
10
nm
Output Power Instability
After 5Hrs/RR=50kHz P=Pmax
≤
5
%
Pulse duration
RR=10kHz P=Pmax
90-110
ns
RR=20kHz P=Pmax
90-120
ns
RR=30kHz P=Pmax
90-120
ns
RR=50kHz P=Pmax
90-130
ns
Pulse setup time
RR=50kHz P=0
~
90% Pmax
<200
us
Pulse off time
RR=50kHz P=100%
~
10%Pmax
<100
us