background image

 

 

 

 

 

 

 

版本号 

 

密级

 

内部 

A0 

 

 

 

 

 

 

 

 

会签

 

阶段 
标记

 

 

 

 

 

 

 

 

       RFL-P120MX       

 

  120MX 激光器英文说明书 

 

    RFL-P120MX·JS02   

 

 

 

部  门 脉冲激光器技术研究部 
 
编  写   胡晓蕾 20210315     
 
校  对   李  莎 20210316     
 
审  核   李  科 20210322     
 
标  审   李其军 20210322     
 
批  准   黄  保 20210322     

 

 

武汉锐科光纤激光技术股份有限公司 

谢良

 

夏巨江

 

刘红 

帅维文 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
旧底图登记号 

底图登记号 

 

Summary of Contents for RFL-P120MX

Page 1: ...密级 内部 A0 会签 阶段 标记 S RFL P120MX 120MX 激光器英文说明书 RFL P120MX JS02 部 门 脉冲激光器技术研究部 编 写 胡晓蕾 20210315 校 对 李 莎 20210316 审 核 李 科 20210322 标 审 李其军 20210322 批 准 黄 保 20210322 武汉锐科光纤激光技术股份有限公司 谢良 夏巨江 刘红 帅维文 旧底图登记号 底图登记号 ...

Page 2: ...User Instruction RFL P120MX Wuhan Raycus Fiber Laser Technologies CO Ltd 2021 ...

Page 3: ...e make sure that the correct voltage of 24V DC is connected and the anode and cathode are right Incorrect polarity or voltage will harm severely the device b The device emits invisible light with a wavelength from 1060nm to 1085nm with average power of 120W Do not expose your eyes or skin to the radiation of the laser c Do not take apart the device because there are no replaceable accessories avai...

Page 4: ...tions 1 1 4 Specifications 2 2 Mounting 4 2 1 Mounting dimensions 4 2 2 Method of installation 4 3 Control Interface 6 4 Operation Regulations 12 4 1 Pre inspection 12 4 2 Operation procedures 12 4 3 Cautions 12 5 Instructions for warranty return and maintenance 13 5 1 General warranty 13 5 2 Limitations of warranty 13 5 3 Service and repairs 13 ...

Page 5: ...tory inspection report 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24V DC 1V power source a Caution Make sure the corresponding wires of the device are properly grounded b All the maintenance to the device should only be done by Raycus because there is no replacement or accessory provided with the device Please do not try to damage the labels or open the cover in...

Page 6: ... make sure the power supply works continuously 1 4 Specifications Table 2 P120MX pulsed fiber laser specifications NO Characteristic Test condition Min Typ Max Unit 1 Mode of operation Pulsed 2 Polarization Random 3 Maximum pulse energy 350ns 80kHz 120W 1 5 mJ 4 Nominal average output power 120 123 105 W 5 Pulse duration Subject to Table 3 10 350 ns 6 Output power adjustment range 0 100 7 Long ter...

Page 7: ...05W 2 20 1 0 2 4W 600 120 105W 2000 120 105W 3 30 1 0 3 4W 395 120 105W 1000 120 105W 4 60 1 0 5 4W 240 120 105W 1000 120 105W 5 100 1 0 8 4W 150 120 105W 1000 120 105W 6 200 1 1 25 4W 95 120 105W 500 120 105W 7 250 1 1 4 4W 85 120 105W 500 120 105W 8 350 1 1 5 4W 80 120 105W 400 120 105W 9 CW 100 1 5 4W 120 105W 500 120 105W 21 Storage Temperature 20 60 22 Humidity 80 23 Power Consumption 450 W 2...

Page 8: ...ion drawing of output isolator Unit mm The output head of the isolator is subject to the final factory product 2 2 Method of installation a Fix the module stable to the bracket and keep the laser in good ventilation b Connect the power line to 24V DC power and ensure enough DC output power Keep it clear to the polarity of the electric current Anode brown Cathode blue PE yellow and green ...

Page 9: ... external controller matches the laser and the control cable is well connected to the laser s interface The recommended electrical connection is shown in Figure 4 Figure 5 Wiring diagram of recommended electrial connection and power supply d The bending radius of the delivery fiber should not exceed 15 cm ...

Page 10: ...m codes in Table 5 17 VCC 5VDC power supply input Providing power for inside isolate chip of DB25 to ensure that the input and output signal are valid 18 EE Emission Enable EE signal HIGH 4 5V Emission Enable LOW or disconnected 1V Emission Disable 19 EM Emission Modulation EM input HIGH 4 5V Emission ON LOW or disconnected 1V Emission OFF 20 Sync Pulse Repetition Rate Synchronization input square...

Page 11: ... signal of the MO Pin19 is the input for the optical output signal The electrical level for both Pin18 and Pin19 are 5V Before turning on Pin 19 MO signal must be switched ON in other word the signal of Pin 18 must be ahead of Pin 19 at least 5 ms and otherwise the laser machine may be damaged e Pin 20 provides control of the frequency The frequency range should be 1kHz 2000 kHz depends on the var...

Page 12: ... factory which can meet the needs of most users Special needs shall be put forward in the customized contract g Definition of alarm signal Table 6 Definition of alarm signal Pin12 Pin11 Pin16 Pin21 Alarm content Low Low Low Laser TemperatureAlarm1 Low Low High Normal High Low Low System Error 2 Low High High Power Error3 1 PS 1 Pin 17 receives external DC voltage to provide power supply for inside...

Page 13: ...nition of Serial Communication Pin Name Description 2 Serial input The setting of the data bits synchronize with rising edge of the serial clock 3 Serial clock Serial clock frequency range 10KHz 100KHz 14 GND Digital GND 16 SO The output data bits synchronize with rising edge of the serial clock 22 Pulse duration control Enable High Enable Pin2 and Pin3 control the pulse duration Low or disconnect...

Page 14: ...t 4 The input data length is 4 bytes the first byte of instruction code should be 0x01 01h the second byte and the third byte are the value of the binary coding of laser duration for example 200 is the decimal number of 0x00C8 represents the setting pulse duration is 200ns 5 Pin22 is the Enable signal The Enable should achieve high state at least 10us before Pin2 and Pin3 changing The Enable shoul...

Page 15: ...n parameter should show up select Fiber in the category of the Laser Control panel follow that select IPG_YLPM and then close this window c Pulse duration can be modified by the Duration on the right side of the window If the setting duration is smaller than the limiting minimum value the duration of output laser will be 2ns minimum If the setting duration is larger than the limiting maximum value...

Page 16: ...is showed in the Table 3 c Laser marking checking For the device initial testing first turn the power down to zero without turning on the marking system after the device is successfully started Then draw a quadrate marking continuously while slowly increasing the power from 1 to 100 at the same time Meanwhile use a ceramic material to observe the laser and the laser should become stronger otherwis...

Page 17: ... not following the instructions caused by those who are not from Raycus Customer has the responsibility to understand and follow this instruction to use the device Any damage caused by fault operating is not warranted Accessories and fiber connectors are excluded in this warranty According to the warranty client should write to us within 31days since the defect is discovered This warranty does not...