4.7.11 DCDC module
The DCDC module page contains the relevant status information of the DCDC module. It
supports up to 12 DCDC modules. The refresh interval of the status information does not exceed
100ms. The data of the DCDC module needs to be forwarded by the main control module, so
only the currently selected page is in the DCDC module, The upper computer software will
automatically read and refresh the status information, reduce the communication frequency, and
avoid occupying too many resources of the main control module.
Figure 22 DCDC module interface
4.8 Control Modes
The laser has two control modes, namely ON mode and REM mode. The user can select the
mode to enter through the key ON the front panel. In ON mode, you can only set the power
percentage, control the light output and light off. In REM mode, you can select AD mode, enable
external control, internal modulation mode, and external modulation mode.
4.8.1 REM mode
AD mode
AD mode
Laser power
ON
12, 14 pin analog voltage 0~10V
0V——0%
10——100%
OFF
The host computer sets the power percentage.