31
Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C20000M-CE
5.4. Guide Laser (Red Guide Beam) Control
In “ON” mode guide laser can only be turned on/off by using Raycus Laser Control System, or
bysending command of “ABN” (on) / “ABF” (off).
The red light module inside the laser works through communication, so there is a time delay of
at least 10ms for the opening and closing of red light
;
When the red light is on, the laser cannot be set to “Ready”. Only after the red light is turned off
the laser can be set to “Ready”. (This limit can be changed, please contact Raycus Engineer).
5.5. Programming Mode
In “ON” mode, when the current program number of the laser is not 0, the laser runs in the
“Programming” mode. Please use the Raycus Host Computer Software to edit the waveform and
select the pre-run program number.
When the laser is in the internal control mode:
Send the “EMON” command or press the
“ON”
button, the laser will start to run the program,
Send the “EMOFF” command or press the
“OFF”
button can terminate the laser emission at anytime
When the laser is in the external control mode, the rising edge of MOD starts to operate
theprogram, and the falling edge of MOD can terminate the program at anytime.
5.6. REM Mode
5.6.1 AD enable mode
When both A1 and A6 of XP1 are set high, the laser operates in AD mode, and the current
laserpower is determined by the analog voltage of pin 1 and pin 2 of xp4; When A6 of xP1 is set low
orsuspended, the current laser power is set by sending "SDC XX" command through PC software
orcommunication.