The flue system must be installed with the regulations in
force.
Maximum flue gas temperature 250°C
(Both burners on)
Minimum flue gas temperature 125°C
(Boiler burner on only)
Chimney Termination
All chimneys should terminate at least 600mm above the
roof level in accordance with current Building Regulations
and statutory requirements as outlined in BS 5410: Part 1,
BS 6461: Part 1 and BS 7566 Parts 1 to 4.
Chimney Cleaning
Ensure there are accessible airtight flue cleaning doors in
order to obtain cleaning access to the complete chimney.
Providing the appliance is operating correctly, an annual
chimney flue cleaning will suffice, but if in doubt arrange
for a half yearly clean, preferably at the beginning/end of
the heating season.
The appliance must only be connected to approved
flue systems. Off the appliance using Schiedel
Ritevent Prima Plus (available in black from AGA-
Rangemaster), and then either ECO ICID or Tecno
Turbo Flex System.
For further information on Schiedel Ritevent Flue
Systems go to www.schiedel.co.uk
Site requirements
10
FLUE SYSTEM
PART No.
SHORT CODE
DESCRIPTION
RO4M996245
R6088
45° ø125mm ELBOW BLACK
RO4M996246
R6089
ø125mm STRAIGHT SECTION BLACK LENGTH 950mm
RO4M996247
R6090
ø125mm STRAIGHT SECTION BLACK LENGTH 450mm
RO4M996248
R6091
ø125mm STRAIGHT SECTION BLACK LENGTH 200mm
*RO4M996249
R6092
* ø125mm x 500mm ADJUSTABLE INNER SECTION -
BLACK
RO4M996252
R6093
LOCKING BAND BLACK (ONE-OFF PER JOINT)
RO4M996253
R6094
VITON SEAL
BLACK PRIMA PLUS FLUE SYSTEM FROM AGA-RANGEMASTER
FOR TYPICAL FLUE INSTALLATIONS PLEASE SEE FIGS. 4 AND 5.
* PLEASE NOTE: The adjustable inner section requires a straight section (950, 450, 200 mm)
to provide adjustability.