Company Confidential
13
Raveon Technologies Corp.
the rear cover, exposing the two circuit boards. The button is in the front
edge of
the radio module’s circuit board.
The default settings that the modem will revert to when the CONFIG button is
pressed are:
1. Serial port 9600 baud, 8 data bits 1 stop, no parity
2. ATCT setting set to 60000 (60 second time-out)
3. Serial port on the front of the unit in RS232 mode, 9600bps, N/8/1.
Even though the serial baud rate reverts to 9600 baud when the CONFIG
button is pressed and the IO port is RS232, it will revert back to the settings
programmed into the
RV-M80-EA2
modem once the Command Mode is
exited.
4.6. Exiting the Command Mode
There are three ways to exit the command mode. They are:
1.
ATCN
Issuing the
ATCN
. The RV-M80-EA2 radio will exit the command
mode, and begin normal operation.
2.
EXIT
Issuing the
EXIT
. The RV-M80-EA2 radio will exit the command
mode, and begin normal operation.
3.
Time Out
. After a pre-set amount of time (60 seconds is the factory
default time), the modem will automatically exit the Command Mode, and
continue normal operation. Changes will not automatically be saved. This
time-out duration may be set with the
ATCT
command.