background image

M7 GX Technical Manual 

19

 

Raveon Technologies Corp. 

6 = Test Points ON 
7 = Transmit CW  
8 = Transmit 1010101… 

AT

TE 

Read product temperature 

– 

Read the internal temperature of 

the unit’s circuit board in degrees Celsius. 

 

-40 to +99 

AT

VB 

Read DC input Voltage

– Returns the DC input voltage reading, 

in mV  (12500 = 12.5VDC input).  

None 

none 

AT

VR 

Firmware Version 

– Returns firmware version currently loaded 

on the module.  

Read Only, 3 
characters 

none  

AT

&F 

Restore Factory

 

– Restore the factory default values.  This 

command will not erase the calibration values.  After this 
command executes, the modem will still be in the CONFIG mode.  

 

 

none 

BAND 

Read the Band 

– Reads the frequency band of the radio. 

First parameter is the text version (UA, UC, VB, …), second 
parameter is the lower limit, and the third parameter is the 
upper limit in MHz. Use to read the band that the radio is 
tuned to cover.  

None 

CONFIG 

Display the M6

’s configuration.   

0, 1, or 2 

CHNUM 

Read number of channels.  

This command will return the 

number of channels this product has.  

 

 

MIMIC 

MIMIC mode.  MIMIC  X Y   X number of seconds to TX if 
input is low.  Y is number of seconds between transmissions 
when the input is high.  

None 

M6 or M6R 

MODEL 

Read Model number.  Read the model number of the unit. 

None 

M6 or M6R 

QSIZE 

Read the number of queued WMX frames in the WMX queue.  

None 

QCLR 

Remove all WMX frames from the WMX frame queue.  

None 

SHOW 

Show/display an overview of the radio’s configuration. 

None 

WMX 

Read/set the WMX serial port protocol.  0=off, 1= enabled. 

 

0, 1

 

WMXVR 

Read the WMX version 

None 

 

WMXINFO 

Read WMX information.  

Returns:

  Aa, bb, ccc, dd  

where

 

AA = Number of WMX message buffers in the product’s WMX 
queue. 
bb = Number of 

WMX messaged queued up in the product’s 

WMX frame queue.  

ccd = Total size of WMX message buffers in bytes. 
dd = WMX version implemented in the product.

  

 

 

 
** indicates values that are calibrated in the factory and are unit-

specific.  If the “Radio 

Type” is changed, these will need to be re

-calibrated.  

 

6.2. 

Data Modem Mode Related Commands 

These commands apply to the operation of the M6 when it is in the data 

modem communication mode.   

Command

 

Command Description

 

Parameters

 

Factory

 

Default 

 

ATBC 

Busy Channel Lock Out – Enable/disable the BCL. If enabled, 
the modem will not transmit on a radio channel that is busy (has 

RF on if).  0-OFF, 1=ON. 

Range: 0-1 

0  

AT

DT

 

Destination Address to call

– Sets address of the modem to 

send data to.  Note, this parameter is entered in HEX format. 
Each digit may be a 0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,or an F.  

Range: 0-FFFF 

1234 

Summary of Contents for RV-M6S

Page 1: ...ential 1 Raveon Technologies Corp RV M6S RV M6G Data Radio Modem Module Optional GPS Tracking Technical Manual Version A8 March 2021 Raveon Technologies Corporation 2320 Cousteau Court Vista CA 92081...

Page 2: ...7 6 2 Data Modem Mode Related Commands 19 6 3 Paging Receiver Related Commands 21 6 4 Factory Default Settings 24 7 Using the M6 in Paging Mode Error Bookmark not defined 7 1 Setting Cap Codes Error B...

Page 3: ...ommands 54 11 3 Center Frequency 55 11 4 TX Deviation 55 11 5 TX Modulation Balance Error Bookmark not defined 11 6 RX Carrier Detect 55 12 Troubleshooting 58 Symptom Unit will not receive 58 Symptom...

Page 4: ...dance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the use...

Page 5: ...dio operator must have the knowledge to control the exposure conditions of its passengers and bystanders by maintaining the minimum separation distance of following range Failure to observe these rest...

Page 6: ...it on a channel frequency within the frequency band it is certified in E You product using this must meet the specific requirements in this manual F Input DC voltage that is low noise 100mV noise and...

Page 7: ...ay be re configured to optimize it for specialized operations extended range or higher data throughput 2 1 Features General Features Serial input and output Programmable serial baud rates up to 115 2k...

Page 8: ...a software based radio and modem There are times an existing unit needs to get updated with a new feature and this can often be done by loading the new firmware into the older radio modem In firmware...

Page 9: ...l Output Low 1K load 0 0 2V Digital Input High 3 0V Digital Input Low 0 3V Enable input High 1 40V DC Input Clean Regulated 7 14V DC Max ripple 25mV AC 3 2 Transmitter Specifications RV M6 xx RF Power...

Page 10: ...eader DC Input 6 14V Clean or regulated contact Raveon for other voltages DC power draw RX mode 600mW DC power draw TX mode 2W 6W DC current draw standby mode 150uA IO Voltage Levels 3 3V digital logi...

Page 11: ...e module High 2 5V to enable it 8 DTR Sleep i Product Sleep input When enabled and used the unit can restart faster than turning the DC power on and off 9 CTS O Clear to send output Indicates state of...

Page 12: ...ided on the module For best RF performance the M6 module should be mounted to the system ground using metal stand offs 4 5 STAT LED Outputs An external dual color LED may be connected to STAT1 and STA...

Page 13: ...command can be used to also force the M6 to utilize a specific Tech Series IO driver The following ATIO commands configure the M6 to assume the IO interfaces connected to its 20 pin header connector A...

Page 14: ...ering a sequence of three plus characters To keep the M6 modem from unintentionally entering the Command Mode because of the pattern occurring in a stream of data entering the modem there must be a pa...

Page 15: ...The modem will respond by listing a brief description of the command To see a list of all commands type HELP Many commands support the MIN and MAX parameters to read the minimum and maximum allowable...

Page 16: ...re are three ways to exit the command mode They are 1 ATCN Issuing the ATCN The M6 radio will exit the command mode and begin normal operation 2 EXIT Issuing the EXIT The M6 radio will exit the comman...

Page 17: ...time period in milliseconds modem returns to normal operation mode from Command mode If the CONFIG button inside the M6 is pressed this parameter will be automatically set to 60000 Range 100 60000mS...

Page 18: ...ntering the serial port and this amo0unt of time passes with no more data the M6 will begin to transmit the data over the air Range 1 999 20 20mS is the default ATR8 Frequency Offset Used to adjust th...

Page 19: ...high None M6 or M6R MODEL Read Model number Read the model number of the unit None M6 or M6R QSIZE Read the number of queued WMX frames in the WMX queue None QCLR Remove all WMX frames from the WMX fr...

Page 20: ...data over the air All RF modems in the network must use the same over the air baud rate Refer to the section Setting the RF Rate for information on how to set the OTA baud rate Range 0 12 0 800 5 960...

Page 21: ...only 2 Transponders Base TX and RX PRAVE output Y 0 for off 1 for on 1 9 2 GXF Display Set Feature GXF X Y Display set or disable various GPS features X is numeric feature code 3 GPS Echo All data fr...

Page 22: ...e disabled Disabled 0 TRIGDX Distance trigger Set a distance in meters threshold beyond which the unit will transmit its position and status If set to 0 the unit always reports at the TXRATE If set to...

Page 23: ...ITS I O Change Reporting Sets reads which bits are used as transmission triggers This is a HEX number Bit 0 is IN0 bit 1 is IN1 IN2 is the serial data input so if the unit is used to send data do not...

Page 24: ...r is the hexadecimal representation of the pins being configured M is the mode for the XX pins Mode M values A Digital TTL Input B Digital TTL Output C Open Drain MOSFET output D DC Power switch outpu...

Page 25: ...ess Mask ATMK FFFF Frequencies Ch 1 462 2125 MHz RV M6R xx Receive Only For the UHF M6R receiver model RV M6R xx the main factory defaults are General Settings Primary Protocol ATMT 0 Packet Data Chan...

Page 26: ...ata will not be passed onto the user 2 Error Correction Automatic error correction may be used M6 modems incorporate an optional ARQ method to re transmit packets with error to ensure the user s data...

Page 27: ...efault serial ports settings are 9600 bps 8 data bits 1 stop and no parity 4 Program the modem s operating frequency to your desired operating frequency This is done with the ATFX xxx xxxxx command Fo...

Page 28: ...to specify the bandwidth settings and Modulation type RF Data Rate Setting X parameter value OTA Bit Rate Symbol Rate Occupied Bandwidth Modulation Type 0 800 800 12 5kHz 2 level GFSK 1 1200 1200 12...

Page 29: ...the data the modem will automatically key its transmitter and send the data over the air Serial Port Baud Rate While the modem is transmitting the user may continue to send more data into the M6 Becau...

Page 30: ...contains a 16 bit address called its Unit Address and is represented as a 4 digit hexadecimal number M6 address may be any number between 0000 and FFFF which is effectively 65 535 different addresses...

Page 31: ...ther is set the Address Mask to 0000 ATMK 0000 command This tells the M6 to ignore the address and receive every transmission Broadcast Transmissions The double FF is used to identify a broadcast pack...

Page 32: ...t important Notes This is the default configuration All units have address 1234 and all modems will talk to all other modems with address 1234 Example 2 a configuration that won t work Sending to Dest...

Page 33: ...the radio can hear on the air REPEAT 0 disables store and forward repeating It is highly recommended that you use this method to configure your M6 as a repeater Important The Unit ID of the repeater m...

Page 34: ...eliable to E D C and G To solve this problem some of the M6 modems are configured as repeaters The still are able to send and receive data but they also will repeat data out to the modems that are out...

Page 35: ...er Table may have up to 4 entries For example M6 B in the above example will have two entries in its Repeater Table The command to set the two entries is ATX1 1020 FFFF 1000 FFFF ARX2 1000 FFFF 1000 F...

Page 36: ...e repeater can do its thing 3 Increase the serial port time out value from 20mS to say 250mS ATR3 250 Then when the polled station responds there is a 250mS delay before the end station s data gets se...

Page 37: ...sponder by reporting is location and status It can receive GPS position reports over the air and output them via its serial port for display or logging 1 Connect a DC power source to the DC IN connect...

Page 38: ...word or phrase 1 16 characters long It is case sensitive DO NOT FORGET WHAT YOU SET IT TO The KEYPHRASE is the only parameter that cannot be read out of the M6G It must be the same as the KEYPHRASE p...

Page 39: ...adio type GX when in the command mode A listing of the GPS features will be displayed An example listing of a M6G in GPS mode 2 is shown below GX GPS mode 2 RavTrack PC Serial Protocol Raveon PRAVE Se...

Page 40: ...n message format OUTPUT x Local NMEA data NMEAOUT x Local NMEA messages NMEAMASK TXRATE xx DATAMUTE x TRIGSPEED xx ATBD X Repeat X Default 0 off Transponder 1 Nothing X 3 No 0 GGA GLL RMC 10 TX only 1...

Page 41: ...the Transmission Report rate Using the TXRATE xx command to set the report rate in seconds for the M6G transponder For example if you wish the M6G to report every 5 minutes set the report rate to 300...

Page 42: ...42 Raveon Technologies Corp GPS Position Transmission Trigger Diagram...

Page 43: ...e state and thus the My reports the state of the bit at the moment the position is transmitted C2 and higher report the latched state of the trigger bit Bits that are designated Trigger Bits are digit...

Page 44: ...the bits Refer to the following table to see the value for x IN 2 TXD IN 1 RTS IN 0 DTR Hexadecimal Representation 0 0 0 0 0 0 1 1 0 1 0 2 0 1 1 3 1 0 0 4 1 0 1 5 1 1 0 6 1 1 1 7 For example to enabl...

Page 45: ...TXRATE is 2 and IDLERATE is 300 then the unit will report in every 2 seconds when an input trigger occurs but will only report in every 5 minutes when input triggers are not happening Important If TR...

Page 46: ...eceiver and transmitter will continue to operate independently of the baud rate When the modem receives a radio signal it will assert the CD hardware signal on the RS 232 serial port if it was configu...

Page 47: ...digits long When you program your own security code into your M6G transponders write it down in a secure place This parameter cannot be read out of the M6G If you forget what it is set to you will ha...

Page 48: ...other M6G modems on the channel but in some other system they probably will not have the same Unit Address and thus will not interfere with your system To reduce the possibility of data cross talk th...

Page 49: ...it ID 1200 through 12FF Sending data with a destination ID of FF34 will be received by any modem with a unit ID of 0034 through FF34 The Address Mask The reason to use hexadecimal digits to represent...

Page 50: ...onfiguration All units have address 1234 and all modems will talk to all other modems with address 1234 Example 2 a configuration that won t work Sending to Destination Address 1236 Receiving Unit Add...

Page 51: ...M6G transponders at ID 0001 The second M6G should be ID 0002 and so on The M6G transponders have internal clocks with 20 ticks per second They can measure time and initiate transmissions 20 times ever...

Page 52: ...Bench Testing Must be in command mode to test Enter at the keyboard to put unit into config test mode ATTD x Various transmit test routines 0 Go back to normal mode Stops the test 1 Random data trans...

Page 53: ...tains All statistics start counting at 0 The ATST 1 command can be used to reset all statistics back to 0 except the run time timers Other operation and configuration statistics are available using th...

Page 54: ...ing that may require adjustment is the center frequency After years of operation all crystals will age and change frequency slightly The ATR8 command is used to adjust the center frequency Like all na...

Page 55: ...et with the ATR8 command 4 Adjust the frequency to the center of the channel with the ATR8 command You can use the U key and the D key to change the settings up and down one value in real time 11 4 TX...

Page 56: ...the radio receiver Mode 1 Data CD In this mode the CD pin is asserted whenever the modem detect a valid data modem signal on the air If RF is present but it is voice or some non data single then the...

Page 57: ...power output at 100 is the full RF power for the board This may vary by model number See the data sheet for maximum RF power levels for various models For a 2W RV M6S radio modem typical RF power lev...

Page 58: ...st use the exact same KEYPHRASE for encryption It is case sensitive Reset the KEYPHRASE setting to a known common phrase Symptom Unit will not transmit Solution 1 Verify that CTS is wired Some devices...

Page 59: ...You may have hardware handshaking enabled on your terminal program but the hardware or cable may not support it Disable hardware handshaking on your terminal program to verify this is the issue Sympt...

Page 60: ...60 Raveon Technologies Corp 13 Mechanical A drawing is shown below...

Page 61: ...amage during shipment l that the Product will be free from any claim for infringement of any patent trademark copyright or other proprietary right including trade secrets RAVEON TECHNOLOGIES INCORPORA...

Page 62: ...the original sales receipt or invoice showing the date location and price of purchase Include a written description of the problem with the product a phone number and name of person who may be contac...

Reviews: