Version C16. February 2013
Raveon Technologies Corporation
Company Confidential
24
transmitter. When set to 4, the receiver is off, but the
transmitter will still transmit GPS positions and data.
ATST
Statistics
–
Show the unit’s operational statistics. See
Statistics section of user manual.
0, 1,2, 3, 4, or 5
None
ATTD
Transmit Test Data
– When issued, the modem will begin
transmitting data. The type of data sent is set in the
parameter. Entering a <CR> will terminate the
transmission.
0 = Go back to normal
1 = Random
3 = 1010… at ¼ baud rate
4 = TX all 0s
5 = TX all 1s
6 = Test Points ON
7 = Transmit CW
8 = Transmit 1010101…
ATTE
Read product temperature
–
Read the internal
temperature of the unit’s circuit board in degrees Celsius.
-40 to +99
-
ATTT
Max Packet Size
–
Set the maximum number of bytes in an
over-the-air packet.
1 - 512
500
ATVB
Read DC input Voltage
– Returns the DC input voltage
reading, in mV (12500 = 12.5VDC input).
None
none
ATVR
Firmware Version
– Returns firmware version currently
loaded on the module.
Read Only, 3
characters
none
ATXn
Show or Configure the Repeat Table
– Set the addresses
that this unit will store-and-forward data to/from. n = 1, 2, 3,
or 4 designating the entry in the table to show or edit..
Four parameters
aaaa bbbb cccc dddd where
aaaa=Source Address
bbbb = S.A. Mask
cccc = Destination Address
dddd = D.A. Mask
ATXR
Enable/Disable Store and Forward Repeating
–
0=disabled, 1
– enabled.
0 or 1
0 (Off)
ATHX
Enable/Disable single-hop repeating
–
0=any number of
repeats, 1
– unit will not repeat a packet that was already
repeated.
0 or 1
0 (multi-hop OK)
ATXT
Read/set repeater delay
–
Read or set the repeater delay
in mS. This is the time between receiving a data packet, and
the time the repeater will re-send it.
0
AT&F
Restore Factory
– Restore the factory default values. This
command will not erase the calibration values. After this
command executes, the modem will still be in the CONFIG
mode.
none
CONFIG
Show Configuration.
Display the settings of every
parameter in the unit. If the parameter is 1, then the help
text is not displayed, If the parameter is 2, the configuration
is output in strictly the format used to program another unit.
None, 1, 2
-
BAND
Show/display the radio band.
Displays the frequency
band that the radio is configured for, along with the upper
and lower frequency, in MHz.. BB is the band code, lll is the
lower frequency in MHz, and uuu is the upper frequency in
MHz.
None
BB, lll, uuu
MODEL
Read Model number.
Read the model number.
None
-
REPEAT
Turn Repeater feature on/off.
If 1, a quick way to enable
repeating all packets. If 0, disables the repeat feature.
0 (off) or 1 (on)
0
RPR
Remote Procedure Request.
Used to request execution of
a command on a remote mode (over the air). See
RV-M7
System Protocol
manual for information on using this
feature.
SHOW
Show/display
an overview of the radio’s configuration.
None
-
WMX
Read/set the WMX serial port protocol. 0=off, 1=
enabled.
0, 1
0